TECHNICAL INFORMATION
MAIN
CODE
SUB
CODE
DESCRIPTION
CHECK
TRANS
LIGHT
INHIBITED OPERATION
DESCRIPTION
32
33
C3 pressure switch open,
3rd range
Yes
DNS, lock in current
range (3rd), DNA
32
55
C3 pressure switch open,
5th range
Yes
DNS, lock in current
range (5th), DNA
32
77
C3 pressure switch open,
Reverse range
Yes
DNS, lock in current
range (R), DNA
33
12
Sump oil temperature
sensor failed low
No
Use default value of
200°F (93°C)
33
23
Sump oil temperature
sensor, failed high
No
Use default value of
200°F (93°C)
34
12
Factory calibration compatibility
number wrong
Yes
DNS, SOL OFF
(Hydraulic default), DNA
34
13
Factory calibration block checksum
Yes
DNS, SOL OFF
(Hydraulic default), DNA
34
14
Power off block checksum
No
Use previous location or
factory calibration and reset
adaptive, DNA
34
15
Diagnostic queue block checksum
No
Use previous location or clear
diagnostic queue, DNA
34
16
Real time block checksum
Yes
DNS, SOL OFF
(Hydraulic default), DNA
34
17
Customer modifiable constants
checksum
Yes
DNS, SOL OFF
(Hydraulic default), DNA
35
0
Power interruption
(code set after power restored)
No
None (Hydraulic default
during interruption)
35
16
Real time
write interruption
Yes
DNS, SOL OFF
(Hydraulic default), DNA
36
0
Hardware/Software
not compatible
Yes
(2)
DNS, SOL OFF
(Hydraulic default), DNA
42
12
Short to battery, A solenoid circuit
Yes
DNS, SOL OFF, DNA
42
13
Short to battery, B solenoid circuit
Yes
DNS, SOL OFF, DNA
42
14
Short to battery, C solenoid circuit
Yes
DNS, SOL OFF, DNA
42
15
Short to battery, D solenoid circuit
Yes
DNS, SOL OFF, DNA
42
16
Short to battery, E solenoid circuit
Yes
DNS, SOL OFF, DNA
42
21
Short to battery, F solenoid circuit
No
Lock-up inhibited, DNA
42
22
Short to battery, G solenoid circuit
Yes
DNS, lock in a range
42
23
Short to battery, H solenoid circuit
No
Differential lock inhibited
(3070 only), retarder inhibited
42
24
Short to battery, J solenoid circuit
No
Low and 1st inhibited
42
26
Short to battery, N solenoid circuit
No
Low and 1st inhibited, allow
retarder
44
12
Short to ground, A solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
13
Short to ground, B solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
14
Short to ground, C solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
15
Short to ground, D solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
16
Short to ground, E solenoid circuit
Yes
DNS, SOL OFF
(Hydraulic default), DNA
8-11