Page 36 FB8X Service Manual Rev. C, 9/28/10
S E R V I C E M E N U
5
5.4.3 Calibrating the Sensors, Switches, and Carriage
Calibrating the Book Sensor
1.
To calibrate the Book Sensor enter the service menu and select CALIBRATION.
2. Select CAL BOOK SENSOR.
3. Make sure there is nothin
g
in the binding recess that can block the Book Sensor. Press the BIND button to calibrate the
sensor.
If the calibration is successful, a result number will appear followed by the message “SUCCESS”.
If the calibration is unsuccessful, a failure message will appear. If a failure message appears double check and make sure there
is nothing blocking the Book Sensor and calibrate again. If you continue to get a failure message, contact Powis Parker
technical support.
Calibrating the Strip Sensor
1.
To calibrate the Strip Sensor enter the service menu and select CALIBRATION.
2. Select CAL STRIP SENSOR.
3. Make sure there is nothing in the binding recess that can block the crescent shaped hole in the Spine heater. Press the
BIND button to calibrate the sensor.
If the calibration is successful, a result number will appear followed by the message “SUCCESS”.
If the calibration is unsuccessful, a failure message will appear. If a failure message appears double check and make sure there
is nothing blocking the crescent shaped hole and calibrate again. If you continue to get a failure message, contact Powis
Parker technical support.
Calibrating the Carriage
1.
To calibrate the Carriage Assembly enter the service menu and select CALIBRATION.
2. Select CAL CARRIAGE.
3. Make sure there is nothing in the binding recess. Press the BIND button.
4. A confirmation message “CAL NOW?” will appear on the display. Press the BIND button to calibrate. The Carriage As-
sembly will move forward twice. A value will briefly appear on the display each time. If the calibration is successful, the
display will say CAL SAVED! followed by a value. This value must be between -64 and +64.
If the calibration is unsuccessful, a failure message will appear. If a failure message appears double check and make sure there
is nothing binding recess and calibrate again. If you continue to get a failure message, contact Powis Parker technical support.
Calibrating the Heaters
NOTE: The heaters must be at room temperature to be calibrated. The binder must be turned off for 1/2 hour- 1
hour for the heaters to return to room temperature. Directing a fan onto the heaters can speed up the cool down
process.
1.
To calibrate the Heaters enter the service menu and select CALIBRATION.
2. Select CAL HEATERS.
3. The fan will turn on for 30 seconds and then the machine will take heater temperature readings for 16 seconds. If the
calibration is successful, the display will say SUCCESS. Press the MENU button to turn off the heaters and stop the
calibration.
If the calibration is unsuccessful, a failure message will appear. If a failure message appears, check that each of the heaters are
plugged in and that the heaters are at room temperature. Calibrate the heaters again. If the failure message appears again,
call Powis Parker technical support.
5 . 4 T E S T I N G A N D C A L I B R A T I O N
Содержание Fastback 8x
Страница 1: ...MODEL 8x DOCUMENT BINDER Service Manual...
Страница 16: ...Page 12 FB8X Service Manual Rev C 9 28 10 O V E R V I E W 2 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...Page 22 FB8X Service Manual Rev C 9 28 10 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 28: ...Page 24 FB8X Service Manual Rev C 9 28 10 S E R V I C E M E N U 5 5 2 S e r v i c e M e n u D i a g r a m...
Страница 29: ...FB8X Service Manual Rev C 9 28 10 Page 25 S E R V I C E M E N U 5 5 2 S e r v i c e M e n u D i a g r a m...