FB8X Service Manual Rev. C, 9/28/10 Page 29
S E R V I C E M E N U
5
5.3.4 INFO
SHOW COUNTS
This menu displays two alternating values for the number of binds the machine has performed and the number of
cycles. Binding a book counts for 1 bind + 1 cycle. Running an autocycle in either Standard or Fast mode, counts
for only 1 cycle.
SHOW VERSION
This menu displays the version of firmware installed in the binder.
5.3.5 HEATERS
HEATER TEST
TEST ALL
Selecting this menu will allow you to turn on and test all three heaters at the same time. Press the BIND
button to turn the heaters on and off. During the heater test, internal diagnostic values will appear on the
display. The diagnostic values are for use by Powis Parker technicians only.
TEST SPINE
Selecting this menu will allow you to turn on the Spine Heater only. Press the BIND button to turn the
heater on and off. During the heater test, internal diagnostic values will appear on the display.
The diagnostic values are for use by Powis Parker technicians only.
TEST BENDER
Selecting this menu will allow you to turn on the Bender Heater only. Press the BIND button to turn the
heater on and off. During the heater test, internal diagnostic values will appear on the display.
The diagnostic values are for use by Powis Parker technicians only.
TEST BACK
Selecting this menu will allow you to turn on the Back Heater only. Press the BIND button to turn the
heater on and off. During the heater test, internal diagnostic values will appear on the display.
The diagnostic values are for use by Powis Parker technicians only.
SET FAN
This menu sets the fan function during heater tests. This menu is for Powis Parker Technicians only.
SHOW HEATER SETS
This menu displays the thermostat values for the three heaters. The first value is for the Spine Heater. This
value should be between 1550 and 2150 . The second value represents the Bender Heater. This value should be
between 1200 and 1700. The third value represents the Back Heater. This value should be between
1200 and 1700.
5 . 3 S e r v i c e M e n u D e s c r i p t i o n s
Содержание Fastback 8x
Страница 1: ...MODEL 8x DOCUMENT BINDER Service Manual...
Страница 16: ...Page 12 FB8X Service Manual Rev C 9 28 10 O V E R V I E W 2 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...Page 22 FB8X Service Manual Rev C 9 28 10 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 28: ...Page 24 FB8X Service Manual Rev C 9 28 10 S E R V I C E M E N U 5 5 2 S e r v i c e M e n u D i a g r a m...
Страница 29: ...FB8X Service Manual Rev C 9 28 10 Page 25 S E R V I C E M E N U 5 5 2 S e r v i c e M e n u D i a g r a m...