English
Electric pallet truck
EGU 14 P; EGU 22 P; EGU 30 P
F8.1.21
Design changes under reserve!
page 26
5. Maintenance Instructions
5.1. Summary: Maintenance and Inspection Works
Maintenance Intervals
Maintenance Works
1
The guiding rollers are provided with long-term lubrication and
are thus virtually maintenance-free.
every 50 operating hours or monthly
2
Grease running paths and lateral faces of guide rollers in the
lifting carriage.
3
Check the level of the hydraulic oil with forks completely low-
ered and the stacker in horizontal position.
4
Check the hydraulic system for leakage, seating of unions and
chafe marks (hoses).
5
Check adjustment of the lifting chain, if necessary adjust,
clean and grease
6
Check seating of all screw connections.
7
Lubricate conical lubrication nipple and turntable bearing.
8
Re-adjust battery pole screws. Check the state of the cell con-
nectors (only with PzS batteries.)
every 200 operating hours or quarterly
9
Check proper state and tight seat of all electric wires for con-
trol current and main current
10
Check the carbon brushes of the electric motor for smooth
running and wear.
11
Check the finger lever for spring pressure and perfect return
movement.
every 500 operating hours or every 6
months
12
Check seating and smooth running of the tie bar.
13
Change hydraulic oil. *)
every 1000 operating hours or annu-
ally
14
Change gear oil. *)
if required, but at least every 6 years
15
Replace hydraulic pressure hoses.
*) New units require the first oil change after max. 20 operating hours.
5.2. Recommended Hydraulic Oil and Lubricant
For perfect function of the electric stacker we recommend to use a hydraulic oil respectively a lubricant as
per the below table. These special oils fulfil best the technical requirements with regard to viscosity (walk
penetration) and pour point.
The lubricants are based on ambient temperatures of - 10° up to + 40°C.
In case of extreme temperatures please contact us or the "Technical Services" of the below-listed mineral oil
companies.
Please also observe our instruction for the operation at low temperatures (see 8.)
Viscosity
class
Rec. working substance for the hydraulic
system Hydraulic Oil HLP-DIN 51524 T2
SO VG 46
Rec. gear oil for wheel hub gear
gear oil CLP-DIN 51517 T3
ISO VG 100
Rec. lubricant for greasing points -
multipurpose grease-
DIN51825 T 1
K 2 K
AGIP
AGIO OSO 32
ROTRA 80W 90M/P
GRM U/2
Energol HLP 37
Hypogear 80W90
BP grease LTX 22
ELF
OLNA 32
Tranself TB
ROLEXA 2; EPEXA 2
Nuto H 32; Nuto HP 32
Gear oil GX 80W90
Esso Beacon 2
Esso GP
Tellus oil 32; Tellus oil S 32
Spirax HD 80 W90
Alvania grease R 2;
Alvania grease 2
IP
IP Hydrus oil 32
IP Pontiax HD 80W90
Athesia GR2; Athesia EP2
Every other reputed brand of lubricant corresponding to the applicable specification of the table may be
used.
Used oil to be disposed according to legal regulations !