Adjus ng
Main
Filtra on
Using the same naviga on and adjustment as Se ng the Time, Filter Cycles are set using a start me and a dura on. Each se ng
can be adjusted in 15
‐
minute increments. The panel calculates the end me and displays it automa cally.
Filtra on
and
Ozone
Pump 1 low and the ozone generator will run during
fi
ltra on.
The system is factory
‐
programmed with one
fi
lter cycle that will
run in the evening (assuming the me
‐
of
‐
day is properly set)
when energy rates are o en lower. The
fi
lter me and dura on
are programmable.
A second
fi
lter cycle can be enabled as needed.
At the start of each
fi
lter cycle, the water will run brie
fl
y to purge the plumbing to maintain good water quality.
Filter
Cycle
2
‐
Op onal
Filtra on
Filter Cycle 2 is OFF by default.
Simply navigate to the Filter Cycle 2 line by pressing the Right Naviga on Bu on, and when “NO” is highlighted, press Up or Down
to toggle Filter Cycle 2 on and o
ff
. When Filter Cycle 2 is ON, it can be adjusted in the same manner as Filter Cycle 1 by naviga ng to
the right.
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall
fi
ltra on by the overlap amount.
Purge
Cycles
In order to maintain sanitary condi ons, as well as protect against freezing, secondary water devices will purge water from their
respec ve plumbing by running brie
fl
y at the beginning of each
fi
lter cycle.
If the Filter Cycle 1 dura on is set for 24 hours, enabling Filter Cycle 2 will ini ate a purge when Filter Cycle 2 is programmed to
begin.
Invert
Panel
Selec ng Invert Panel will
fl
ip the display and the bu ons so the panel can be easily operated from inside or outside the spa.
Restric ng
Opera on
The control can be restricted to prevent unwanted use or temperature adjustments. Locking the Panel prevents the controller from
being used, but all automa c func ons are s ll ac ve. Locking the Se ngs allows Jets and other features to be used, but the Set
Temperature and other programmed se ngs cannot be adjusted. Se ngs Lock allows access to a reduced selec on of menu
items. These include Set Temperature, Invert, Lock, U li es, Informa on and Fault Log. They can be seen, not changed or edited.
Locking
&
Unlocking
Lock
1) Scroll to se ng, press select bu on.
2) Scroll to lock, press select bu on.
3) Press > to Se ng.
4) Press select bu on.
5) “Se ng” will light and be ac vated.
6) Press < key, press select bu on twice.
Unlock
1) Scroll to se ng, press select bu on.
2) Scroll to Lock, press select bu on.
3) Highlight either Se ng or Panel.
4) Press > key
5) Press select bu on twice, press
v
key.
6) Press <, press select bu on twice.