Opera on Systems
Vitality™ Series | SL
‐
Accent™ Control
41
Once the GFCI is tripped manually, reset the GFCI and the spa will operate normally from that point.
Warning:
The end
‐
user must be trained to expect this one
‐
me test to occur and how to properly reset the GFCI or RCD. If freezing
condi ons exist, the GFCI or RCD should be reset immediately or spa damage could result.
General
Water
Temperature
is
Unknown
A er the pump has been running for 1 minute, the temperature will be displayed.
Too
Cold
–
Freeze
Protec on
A poten al freeze condi on has been detected and pump is ac vated. The pump is ON for at least 4 minutes a er the poten al
freeze condi on has ended. In some cases, the pump may turn on and o
ff
and the heater may operate during Freeze Protec on.
This is an opera onal message, not an error indica on.
Water
is
too
Hot
(OHS)
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa func ons are disabled. System will auto reset when
the spa water temp is below 108°F (42.2°C). Check for extended pump opera on or high ambient temp.
Heater
‐
Related
Heater
Flow
is
Reduced
(HFL)
There may not be enough water
fl
ow through the heater to carry the heat away from the hea ng element. Heater start up will
begin again a er about 1 min. See “Flow Related Checks” below.
Heater
Flow
is
Reduced
(LF)*
There is not enough water
fl
ow through the heater to carry the heat away from the hea ng element and the heater has been
disabled. See “Flow Related Checks” below. A er the problem has been resolved, you must press any bu on to reset and begin
heater start up.
Содержание Summit Series
Страница 1: ...S S F S O M R 2020 01 1 800 451 1420 pdcspas com support pdcspas com ...
Страница 2: ......