background image

 

Regular Maintenance 

80

 

 

Thermal

 

Cover

 

Care

 

 

 

Always use the locking thermal cover when not in use to reduce heat

up  me, opera ng costs and keep unwanted out.  To              

 

prolong the life of the cover, handle it with care and clean it regularly using mild soap and water. Periodic treatments with a vinyl              

 condi oner will help protect against deteriora on caused by UV rays from the sun. Never allow anyone to stand or sit on the cover, 
 

and avoid dragging it across rough surfaces. Be sure to lock all straps when not in use for safety and to prevent wind damage. Keep 

 

cover open at least 15 minutes a er adding chemicals. 

 

Access the web for further details on proper care and maintenance, replacement  and use of the cover. 

 
 

 

EverPure2™

 

Ozone

 

and

 

UV

 

Care

 

 

 

The ozone hose and check valve connec on between the ozone generator and ozone injector should be inspected or replaced, if 

 

necessary, annually.  The air quality pulled into the generator may cause rapid wear on the hose and check valve.  The EverLite2™ 

 

will light green when the ozone generator is opera ng (during the 

fi

ltra on cycle) indica ng the EverPure2™ system is indeed               

 sani zing the water. 
 
 The 

UV

C bulb is es mated to be opera ve for about 1000 hours of use.  Access the website for further informa on on proper                

 opera on and replacement of this system. 
 

 

Plumbing

 

Care

 

 

 

Swim spas are plumbed with plas c jets, pipes and 

fi

ngs which are glued together. These plas c parts and their many glue 

 

joints are subjected to harsh treatment with years of opera on, subjected to many hot

cold cycles and the high pressure             

 

generated by the powerful jet pump stressing pipes and joints. Although the factory has a rigorous tes ng procedure, even  

 transporta on from the factory to you can cause vibra on and possible loosening of the joints. 

 

 

Should a leak occur, remove that appropriate sec on of cabinet wall exposing the leaking area.  Drain the swim spa to below the 

 

leak and contact a quali

fi

ed technician for repair. 

 

 

Filter

 

Cartridge

 

Care

  

 

 

Swim Spa water 

fi

ltra on begins as soon as the 

fl

ow is steady through the pump.  As the 

fi

lter cartridge removes dirt from the water, 

 

the accumulated debris will cause a resistance to 

fl

ow. When this is no ced, along with cloudy water, clean or replace the  

fi

lter           

 

element as noted below. This generally occurs monthly depending upon use and water care. 

 

 

Pris ne™

 

System:

 

Suc on

side design

 

 

1. Shut o

 power at the main or sub panel. 

 2. 

Remove 

the 

fi

lter housing top by pulling up the raised por ons of the 

fi

lter top.   

 

 3. 

Li  the skimmer basket out of the 

fi

lter canister. 

 4. 

Remove 

the 

fi

lter from the canister. 

 

5. Replace with clean 

fi

lter, either a clean spare which is recommended, or cleaning of the soiled removed cartridge.  Refer to        

 scheduled 

care 

sec on for recommenda ons. 

 

6. Place skimmer basket back in 

fi

lter canister. 

 7. 

Place 

fi

lter top onto 

fi

lter canister and turn clockwise un l top stops. 

 

 

 

 

Swim

 

Spa

 

Acrylic

 

Surface

 

Care

  

 

 

To preserve the sheen of the acrylic surface, clean and sani ze with clean water to remove any par cles and use rubbing alcohol 

 

or a non

abrasive, non

sudsing cleaner to wipe clean.  Use a so , lint free cloth and never use an aggressive solvent such as a               

 

lacquer thinner or acetone which will cause damage to the acrylic. 

Содержание Summit Series

Страница 1: ...S S F S O M R 2020 01 1 800 451 1420 pdcspas com support pdcspas com ...

Страница 2: ......

Страница 3: ...y Series SL Accent Control 36 44 Synergy Series FX ProView Control 45 51 Summit Series SX SmartTouch Control 52 71 WiFi Op on 72 Fitness Guide 73 Aqua c Fitness Equipment 74 75 Water Chemistry Basics 76 Maintenance 77 78 Swim Spa Care Regular Maintenance 79 80 Periodic Draining 81 Winterizing 81 Troubleshoo ng 82 Maintenance Records 83 84 Swim Spa Owner s Manual Plas c Development Company Inc 3743...

Страница 4: ...t prior no ce To be aware of any of these possible changes log on to www pdcspas com referring to the Customer Care sec on or contact your retailer directly Ownership Informa on Name ___________________________________________________ Address ___________________________________________________ ___________________________________________________ Installa on Date ____ ____ ____ Model Name __________...

Страница 5: ...a on according to codes are required for proper installa on and user sa sfac on It is recommended that a licensed contractor perform the installa on Warranty is voided for improper installa on related issues WARNING REPLACE ALL SAFETY SUCTION COVERS EVERY 7 YEARS Replace with similar VGB approved fi ngs at same or higher flow ra ngs Replacement applies to all swim and fitness spa models both round...

Страница 6: ...the swim spa must be bonded to the home bonding grid GROUND FAULT CIRCUIT INTERRUPTER PROTECTION or equivalent RCD for export installs All PDC Spas swim spas are permanently installed units GROUND FAULT CIRCUIT INTERRUPTER PROTECTION IS REQUIRED All swim spa equipment systems must be protected by a class A ground fault circuit interrupter GFCI or equivalent RCD for export installs A ground fault c...

Страница 7: ...wim spa should be tested prior to each use by the homeowner With the swim spa in opera on push the test bu on on the GFCI circuit breaker at the panel box The swim spa should shut down immediately Now reset the GFCI The swim spa should return to normal opera on If the GFCI fails to operate in this manner there exists a possibility of electrical shock Approved tes ng applies for export protec on de...

Страница 8: ... important for persons over the age of 35 or persons with pre exis ng health problems such as obesity heart disease high blood pressure circulatory problems or diabetes to consult their physician before using the swim spa The swim spa jets produce a stream of water with rela vely high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin Never insert any object ...

Страница 9: ... qualified service personnel 8 This unit should be subjected to periodic rou ne maintenance for example once every 3 months to make sure that the unit is opera ng properly ADDITIONAL SAFETY CONSIDERATIONS Install the swim spa to provide drainage for compartments of electrical components For floor recessed swim spas Install to permit access for servicing from above or below the floor Swim spa equip...

Страница 10: ...is sign immediately upon installa on No fy the factory or your retailer should you require addi onal signs or replacements WARNING Read all instruc ons before using the swim fitness spa PDC Spas assumes no responsibility for personal injury or property damage sustained by or through the use of this product SAVE THIS MANUAL SIGNS AND INSTRUCTIONS FOR FUTURE REFERENCE Important It is extremely impor...

Страница 11: ...ls Fi ngs mounted on the lip of swim spa controlling amount of outside air mixed with incoming water of the hydrotherapy jet Your swim spa has mul ple air control on the swim spa lip that control air water mix for a segment of the jets You choose the strength that best suits you When not in use the air controls should be kept in the off posi on Suc on Circular fi ng mounted on the ver cal wall of t...

Страница 12: ...r to the Control sec on of this manual for programming of personalized propulsion speed for custom workouts ProView and Accent Controls Used to control all swim spa func ons The topside is used to control the water temperature pumps spa light programmable filtra on cycles and func ons The topside will display between the water temperature and the me as well as display error codes rela ng to servic...

Страница 13: ... onal on Synergy and Summit Series models only This package includes up to 13 topside air and diverter controls enhancing opera on during nigh me use EverLite2 Exclusive to all PDC swim and fitness spa models is the cabinet mounted sight glass which confirms the EverPure2 ozone and UV purifica on system are properly opera ng Dual zone models also feature this sight glass on the hot tub zone equipp...

Страница 14: ...Acrylic Dimensions Domestic 144 x 92 x 56 Dimensions Export 366 cm x 234 cm x 142 cm Water Capacity 1 792 gallons 6 784 liters Dry Weight 1 316 lbs 597 kg Skirt Material Permawood Water Flow 230 GPM Fitness Length 94 approx Not every jet is referenced Each type of jet is noted for ease of identification Note location of audio components prior to install All specifications are accurate at time of p...

Страница 15: ...Fitness Length 76 approx Not every jet is referenced Each type of jet is noted for ease of identification Note location of audio components prior to install All specifications are accurate at time of print Manufacturer reserves the option to change product without prior notice Dimensions are approximate WATER SYSTEM photo ref EverPure2 Treatment System OZ 1 Pristine Filter F 2 Slide Valves 2 Elite...

Страница 16: ...h type of jet is noted for ease of identification Note location of audio components prior to install All specifications are accurate at time of print Manufacturer reserves the option to change product without prior notice Dimensions are approximate WATER SYSTEM photo ref EverPure2 Treatment System OZ 1 Pristine Filter F 2 Slide Valves 2 Elite Pro Jet S 1 Euro Jet w Eyeball E 8 Mega ssage Jet G 4 O...

Страница 17: ...eferenced Each type of jet is noted for ease of identification Note location of audio components prior to install All specifications are accurate at time of print Manufacturer reserves the option to change product without prior notice Dimensions are approximate WATER SYSTEM photo ref EverPure2 Treatment System OZ 1 Pristine Filter F 2 Slide Valves 2 Elite Pro Jet S 1 Euro Jet w Eyeball E 18 Mega s...

Страница 18: ...Pump 2 3 6 0 HP 6 0 HP Electronics Electrical Can 6 501X1 Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 KW Operation System Main Spa Side Control 7 FX ProView Control Neo 2100 Series WATER SYSTEM photo ref EverPure2 Treatment System UV C 1 Pristine Filter F 2 Slide Valves 6 Large Euro Jet w Eyeball E 26 Mega ssage Jet G 10 Ozone Jet O 2 Diverter Valves V 1 Safety Suction U 6...

Страница 19: ...stic 180 x 92 x 56 Dimensions Export 427 cm x 234 cm x 142 cm Water Capacity 2 240 gallons 8 479 liters Dry Weight 1 645 lbs 746 kg Skirt Material Permawood Water Flow 647 GPM Fitness Length 130 approx Not every jet is referenced Each type of jet is noted for ease of iden fica on Note loca on of audio components prior to install All specifica ons are accurate at me of print Manufacturer reserves t...

Страница 20: ...HP 6 0 HP Electronics Electrical Can 6 501X1 Waterway Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 KW Operation System Main Spa Side Control 7 FX ProView Control Waterway Neo 2100 Series WATER SYSTEM photo ref EverPure2 Treatment System UV C 1 Pristine Filter F 2 Slide Valves 6 Large Euro Jet w Eyeball E 26 Mega ssage Jet G 10 Ozone Jet O 2 Diverter Valves V 1 Safety Suctio...

Страница 21: ...ard Stainless Steel Jetting Standard Eclipse LED cabinet lighting Optional BlueTune Audio Optional Oasis LED lighting Optional ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Spa Pump 1 4 0 HP 4 0 HP Swim Pump 1 2 6 0 HP 6 0 HP Swim Pump 2 3 6 0 HP 6 0 HP Electronics Electrical Can 6 501X1 Waterway Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 K...

Страница 22: ...ump 2 5 6 0 HP 6 0 HP Electronics Electrical Can spa end swim end 6 7 100X1 501X1 Waterway Neo 2100 Series each Voltage spa end swim end 240 240 230 230 Amperage spa end swim end 50 50 1x32 1x32 Heater spa end swim end H1 H2 5 5 KW 5 5KW 3 0 KW 3 0 KW Operation System Spa Side Control spa end swim end 8 9 ProView FX ProView Waterway Neo 2100 Series each SPECIAL FEATURES Spa Pillows 3 Highlights2 L...

Страница 23: ...01X1 Waterway Neo 2100 Series each Voltage spa end swim end 240 240 230 230 Amperage spa end swim end 50 50 1x32 1x32 Heater spa end swim end H1 H2 5 5 KW 5 5KW 3 0 KW 3 0KW Operation System Spa Side Control spa end swim end 8 9 ProView FX ProView Waterway Neo 2100 Series each SPECIAL FEATURES Spa Pillows 2 Highlights2 LED lighting Standard Stainless Steel Jetting Standard Eclipse LED cabinet ligh...

Страница 24: ... HP Electronics Electrical Can 6 501X1 Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 KW Operation System Main Spa Side Control 7 SX SmartTouch Control Neo 2100 Series Swim Pump 3 4 6 0 HP 6 0 HP WATER SYSTEM photo ref EverPure2 Treatment System UV C 1 Pristine Filter F 2 Slide Valves 8 Large Euro Jet w Eyeball E 26 Mega ssage Jet G 10 Ozone Jet O 2 Diverter Valves V 1 Safety...

Страница 25: ...ons Domestic 180 x 92 x 56 Dimensions Export 427 cm x 234 cm x 142 cm Water Capacity 2 240 gallons 8 479 liters Dry Weight 1 725 lbs 782 kg Skirt Material Permawood Water Flow 877 GPM Fitness Length 130 approx Not every jet is referenced Each type of jet is noted for ease of iden fica on Note loca on of audio components prior to install All specifica ons are accurate at me of print Manufacturer re...

Страница 26: ...cs Electrical Can 6 501X1 Waterway Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 KW Operation System Main Spa Side Control 7 SX SmartTouch Control Waterway Neo 2100 Series Swim Pump 3 4 6 0 HP 6 0 HP WATER SYSTEM photo ref EverPure2 Treatment System UV C 1 Pristine Filter F 2 Slide Valves 8 Large Euro Jet w Eyeball E 26 Mega ssage Jet G 10 Ozone Jet O 2 Diverter Valves V 1 S...

Страница 27: ...el Jetting Standard Eclipse LED cabinet lighting Optional BlueTune Audio Optional Oasis LED lighting Optional ELECTRICAL SYSTEM Pump Information Reference Number Domestic 60Hz Export 50Hz Spa Pump 1 4 0 HP 6 0 HP Spa Pump 1 2 6 0 HP 6 0 HP Spa Pump 2 3 6 0 HP 6 0 HP Electronics Electrical Can 6 501X1 Waterway Neo 2100 Series Voltage 240 230 Amperage 50 1x32 Heater H 5 5 KW 3 0 KW Operation System ...

Страница 28: ...ronics Electrical Can spa end swim end 6 7 100X1 501X1 Waterway Neo 2100 Series each Voltage spa end swim end 240 240 230 230 Amperage spa end swim end 50 50 1x32 1x32 Heater spa end swim end H1 H2 5 5 KW 5 5KW 3 0 KW 3 0 KW Operation System Spa Side Control spa end swim end 8 9 ProView SX SmartTouch Waterway Neo 2100 Series each Swim Pump 3 10 6 0 HP 6 0 HP SPECIAL FEATURES Spa Pillows 3 Highligh...

Страница 29: ...nics Electrical Can spa end swim end 6 7 100X1 501X1 Waterway Neo 2100 Series each Voltage spa end swim end 240 240 230 230 Amperage spa end swim end 50 50 1x32 1x32 Heater spa end swim end H1 H2 5 5 KW 5 5KW 3 0 KW 3 0KW Operation System Spa Side Control spa end swim end 8 9 ProView SX SmartTouch Waterway Neo 2100 Series each Swim Pump 3 10 6 0 HP 6 0 HP SPECIAL FEATURES Spa Pillows 2 Highlights2...

Страница 30: ...l damage to the swim spa resul ng from the incorrect installa on of placement on inadequate founda on is not covered in the swim spa s limited warranty General Considera ons Make sure your dimensions are correct as you prepare the site for your new swim spa Click onto the web site www pdcspas com or call your retailer for dimensions of the model you have chosen Allow a perimeter of the chosen grou...

Страница 31: ...f swim spa removal 7 Read 7 13 in the Outdoor Installa on Considera ons 8 Do not set swim spa on finished floor without a waterproof barrier protec on underneath 9 The swim spa should have access to a power source capable of supplying 240 volts AC power It must be wired directly into a grounded circuit with a Ground Fault Circuit Interrupter G F C I or equivalent RCD not supplied for export instal...

Страница 32: ...es A swim spa may be installed within 5 feet of metals surfaces providing each metal surface is permanently connected by a No 6AWG 8 4 mm2 copper conductor a ached to the wire connector on the terminal box provided for this purpose ALL INSTALLATIONS MUST COMPLY WITH ARTICLE 680 OF THE U S NATIONAL ELECTRIC CODE AND ANSI NFPA 70 1984 Par ally or Fully Recessed Installa ons PDC Spas does not recomme...

Страница 33: ...ts Water with high mineral count may discolor the water once a sani zer is added 6 Let the water run out of your garden hose for several minutes before filling the swim spa This will flush out stagnant water in the line that may cause bacteria 7 Begin filling the swim spa We recommend filling the swim spa to the top line on side wall During the filling process periodically check the unions to ensu...

Страница 34: ... straps on the swim spa cover and hold latch against the cabinet side panel To posi on the lock correctly have a second person hold the strap ght on the opposite side of the swim spa cover The swim spa cover must be ght Do not place the latch over the grooves of the cabinet finish Remove the latch from the lock a ach the lock to the cabinet side panel with three 4 screws provided A ach the other l...

Страница 35: ...l electrical supplies and contact a qualified technician before servicing All swim spa installa ons are to be performed by a licensed electrician and in accordance with all local and na onal codes Swim Fitness Spa Wiring Schema c for Cer fied Electricians Reference Only Wire A Wire B O 1 Main Panel Circuit Breaker G F C I Swim Spa Disconnect Wire A Wire B Op on 2 Main Panel Circuit Breaker Swim Sp...

Страница 36: ...o Swim Spa Load 120V Red To Swim Spa Load Neutral White To Swim Spa To Swim Spa OUTPUT Line BLACK House Input Line RED House Input Pig Tail WHITE From GFCI Breaker Going to Neutral Bar in Box Load Neutral Bar Line Neutral WHITE House Input From House INPUT IMPORTANT 6 Gauge Copper Wire MUST Be Used Test GFCI Monthly and Prior to Each Use ATTENTION ELECTRICIAN All PDC Swim Spa Units must be install...

Страница 37: ...opera on and protec on of swim spa occupants IMPORTANT 6 Gauge Copper Wire MUST Be Used Test GFCI Monthly and Prior to Each Use Connec ng Power to Swim Spa Pack QUALIFIED ELECTRICIAN ONLY Confirm the circuit being used for swim spa power is GFCI protected either at main panel box or at disconnect Verify that power is off to outside disconnect GFCI Determine how wire is to enter swim spa cabinet Rou...

Страница 38: ...per opera on and protec on of swim spa occupants IMPORTANT 10 Gauge 2 59mm Copper Wire MUST Be Used Test RCD Monthly and Prior to Each Use NEUTRAL GROUND LINE STRAIN RELIEF Connec ng Power to Swim Spa Pack QUALIFIED ELECTRICIAN ONLY Confirm the circuit being used for swim spa power is RCD protected either at main panel box or at disconnect Verify that power is off to outside disconnect RCD Determin...

Страница 39: ...l has separate WARM Up and COOL Down temperature bu ons The MENU Bu on is used to choose the various menus and navigate each sec on The two Temperature bu ons Warm and Cool are used to select and change the parameter Typical use of the Temperature bu ons allows changing the Set Temperature while the numbers are flashing in the LCD The menus can be exited by pressing the Menu key repeatedly to retu...

Страница 40: ...ily turning the pump off and on will help it to prime Do not do this more than 5 mes If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mode Doing so may cause damage to the pum...

Страница 41: ...mmon use being a ready to use se ng vs a vaca on se ng The Ranges are chosen using the menu structure below Each range maintains its own set temperature as programmed by the user This way when a range is chosen the spa will heat to the set temperature associated with that range For example High range might be set between 80 F and 104 F Low range might be set between 50 F and 99 F Freeze protec on ...

Страница 42: ...ntrol can be restricted to prevent unwanted use or temperature adjustments Locking the panel prevents the controller from being used but all automa c func ons are s ll ac ve Locking the Temperature allows Jets and other features to be used but the Set Temperature and other programmed se ngs cannot be adjusted Temperature Lock allows access to a reduced selec on of menu items These include Set Temp...

Страница 43: ... Filter Cycle 2 1 Repeatedly press menu un l FLTR2 appears 2 Press up arrow 3 Press up arrow again to turn on 4 Repeat step for se ng filter 1 Purge Cycles In order to maintain sanitary condi ons the pump will purge water from plumbing by running briefly at the beginning of each filter cycle If Filter Cycle 1 is set for 24 hours enabling Filter Cycle 2 will ini ate a purge when Filter Cycle 2 is p...

Страница 44: ...he pump may turn on and off and the heater may operate during Freeze Protec on This is an opera onal message not an error indica on Water is too Hot OHS The system has detected a spa water temp of 110 F 43 3 C or more and spa func ons are disabled System will auto reset when the spa water temp is below 108 F 42 2 C Check for extended pump opera on or high ambient temp Heater Related Heater Flow is ...

Страница 45: ... below 108 f 42 2 C See Flow Related Checks below A Reset Message may appear with other Messages Some errors may require power to be removed and restored Flow Related Checks Check for low water level suc on flow restric ons closed valves trapped air too many closed jets and pump prime On some systems even when spa is shut down by an error condi on some equipment may occasionally turn on to con nue...

Страница 46: ...rvice organiza on if this message appears on more than one power up Memory Failure Clock Error Contact your dealer or serviceorganiza on Configura on Error Spa will not Start Up Contact your dealer or service organiza on The GFCI Failure System Could Not Test the GFCI North America Only May indicate an unsafe installa on Contact your dealer or service organiza on A Pump Appears to be Stuck ON Wate...

Страница 47: ...I or RCD European will have a TEST and RESET bu on on it that allows a user to verify proper func on WARNING If freezing condi ons exist a GFCI or RCD should be reset immediately or spa damage could result The end user should always be trained to test and reset the GFCI or RCD on a regular basis Change the water May appear on a regular schedule i e every 90 days Change the water in the spa on regu...

Страница 48: ...cilitate priming If the pumps have not primed a er 2 minutes and water is not flowing from the jets in the spa do not allow the pumps to con nue to run Turn off the pumps and repeat the process Note Turning the power off and back on again will ini ate a new pump priming session Some mes momentarily turning the pump off and on will help it to prime Do not do this more than 5 mes If the pump s will not...

Страница 49: ...on to choose an item Selec ng one of these items will change to a different screen with ad di onal controls One Press Ac va on The Shortcut Screen requires no naviga on Each bu on is fixed on a specific func on and can be used as a very simple user interface for the spa Messages At the bo om of the screen messages may appear at various mes Some messages must be dismissed by the user Press and Hold ...

Страница 50: ...temperature un l the heater pump has been run ning for a minute or two While Pump 1 High can be turned on and off Pump 1 Low will run un l set temperature is reached or 1 hour has passed Ready in Rest Mode READY REST appears in the display if the spa is in Rest Mode and the Jets 1 Bu on is pressed It is assumed that the spa is being used and will heat to set temperature While Pump 1 High can be tur...

Страница 51: ...e Cycles In order to maintain sanitary condi ons as well as protect against freezing secondary water devices will purge water from their respec ve plumbing by running briefly at the beginning of each filter cycle If the Filter Cycle 1 dura on is set for 24 hours enabling Filter Cycle 2 will ini ate a purge when Filter Cycle 2 is programmed to begin Invert Panel Selec ng Invert Panel will flip the ...

Страница 52: ... to provide freeze protec on The water devices will run either con nuously or periodically depending on condi ons GFCI Test The Ground Fault Circuit Interrupter GFCI or Residual Current Detector RCD is an important safety device and is required equipment on a spa installa on CE registered systems do not have an RCD Test Feature due to the nature of the electrical service The end user must be train...

Страница 53: ...een resolved you must clear the message to restart heater start up See Flow Related Checks below The heater is too hot One of the water temp sensors has detected 118 f 47 8 C in the heater and the spa is shut down You must clear the message when water is below 108 f 42 2 C See Flow Related Checks below Flow Related Checks Check for low water level suc on flow restric ons closed valves trapped air ...

Страница 54: ... service organiza on Reminders General maintenance helps Reminder Messages can be suppressed by using the Preferences Menu Clean the filter May appear on a regular schedule i e every 30 days Clean the filter media as instructed by the manufacturer Test the GFCI or RCD May appear on a regular schedule i e every 30 days The GFCI or RCD is an important safety device and must be tested on a regular ba...

Страница 55: ...ump priming session Some mes momentarily turning the pump off and on will help it to prime Do not do this more than 5 mes If the pump s will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run without priming for more than 2 minutes Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4 5 minute priming mo...

Страница 56: ...ed The selected Temperature Range is indicated in the upper le corner Time of Day Ozone and Filter status is available along with other messages andalerts The Spa Equipment Control Icon will spin if any pump is running A Lock icon is visible if the panel or se ngs are locked ICON Specifica ons 1 H High Temperature Range 2 R Ready Mode 3 F1 Filter Cycle 1 Running 4 O3 Ozone Running 5 C Cleanup Cycl...

Страница 57: ...0 Music is Ac ve Music is Inac ve Music is Disabled 11 Message Wai ng Indicator The Message Wai ng Indicator will show one of the following icons Touch the Indicator to go to a Message Screen which shows the message Some messages will include the Call for Service text as it requires a service technician to fix the problem If the panel is locked and a message alert appears you will be taken to the ...

Страница 58: ...can switch between low speed and high speed but you cannot turn the heater pump off A er 1 hour the System will revert to Rest Mode This mode can also be reset by selec ng the Heat Mode line Se ngs Programming Etc The Se ngs Screen is where all programming and other spa behaviors are controlled Each icon on the Se ngs screen takes you to a different screen where one or more se ng may be viewed and o...

Страница 59: ... and displays it automa cally The Filter Icon on the Se ngs Screen takes you to a screen where you control the Filter Cycles Filter Cycle 2 Op onal Filtra on Filter Cycle 2 is OFF by default Press 1 to view Filter 1 Press 2 once to view Filter 2 Press 2 again to turn Filter 2 ON or OFF When Filter Cycle 2 is ON it can be adjusted in the same manner as Filter Cycle 1 It is possible to overlap Filte...

Страница 60: ...o disable the pumps during service func ons like cleaning or replacing the filter Hold Mode will last for 1 hour unless the mode is exited manually If spa service will require more than an hour it may be best to simply shut down power to the spa The Hold Icon on the Se ngs Screen places the spa in Hold Mode and displays the System Hold screen Touch Back to exit Hold Mode Set Temperature Press Up o...

Страница 61: ...n bu on is shown and pressed when on an edi ng page and a value has been selected highlighted the value can be incremented by pressing the up arrow or decremented by pressing the down arrow Common Bu ons Exi ng Screens The Back bu on is on every screen except the Main Screen the Priming Mode Screen are a Message Display Screen When you see only this bu on or this bu on plus an Inac ve Save Bu on i...

Страница 62: ...r cycle the water devices like blower and other pumps will run briefly to purge the plumbing to maintain good water quality Clean Up Cycle When a pump is turned on by a bu on press a clean up cycle begins 30 minutes a er the pump is turned off or mes out The pump and the ozone generator will run for 30 minutes or more depending on the system On some systems you can change this se ng Freeze Protec o...

Страница 63: ...e hot tub off at the breaker and contact service tech Units Screen The Units Icon on the Se ngs Screen takes you to the Units Screen 1 Press Temp Display to change the temperature between Fahrenheit and Celsius 2 Press Time Display to change the clock between 12 hr and 24 hr display Reminders The Reminder Icon on the Se ngs Screen takes you to the Reminders screen Press Reminders to turn the remind...

Страница 64: ...ry the heat away from the hea ng element Heater start up will begin again a er about 1 min See Flow Related Checks below The Water Flow had Failed M017 There is not enough water flow through the heater to carry the heat away from the hea ng element and the heater has been disabled See Flow Related Checks below A er the problem has been resolved reset the message The Heater may be Dry M028 Possible...

Страница 65: ...age appears on more than one power up The clock has failed M020 Contact your dealer or service organiza on Configura on error Spa will not Start Up Contact your dealer or service organiza on The GFCI test failed System Could Not Test the GFCI M036 North America Only May indicate an unsafe installa on Contact your dealer or service organiza on A Pump may be Stuck On M034 Water may be overheated POW...

Страница 66: ...CD will have a TEST and RESET bu on on it that allows a user to verify proper func on Change the water May appear on a regular schedule i e every 90 days Change the water in the spa on regular basis to maintain proper chemical balance and sanitary condi ons Clean the cover May appear on a regular schedule i e every 180 days Vinyl covers should be cleaned and condi oned for maximum life Change the ...

Страница 67: ...m Timed Workout Workout Settings Manual Workout Menu Overview Manual Workout requires you to manually set the swim speed during the workout The swim speed can be changed at any me you desire The workout runs un l you stop it or the workout mes out a er one hour from the last me you changed the speed se ng Run Manual Workout On the swim panel go to the Swim Menu and navigate to the Manual Workout s...

Страница 68: ...ge 1 2 The workout will begin automa cally and will show you both Elapsed Time and Time Remaining E The Speed G can be changed during the workout by pressing the Up Down Arrows G The workout can be paused by pressing Pause H and restarted by pressing the same bu on H again Image 2 3 The workout will stop either when the me is up or when Stop I is pressed The program can be restarted by pressing Re...

Страница 69: ...and them save them as a User Workout Basic Long Interval Short Interval Half Life Peak and Random these programs are predefined where the only variables that can be changes are the Dura on and the Difficulty Selec ng a Workout Program In the example below select a random workout Follow these steps to operate any workout from the list Random Workout Follow these steps to run a Random workout 1 Select...

Страница 70: ...ue every me it is chosen it is necessary to save a Random workout that you like prior to star ng it It will be stored as a User Workout to select this workout see sec on on Using Your Created Workout Follow these steps to save a Random workout 1 Press the edit bu on F image 1 2 Press the save bu on G Image 2 Workout Random Image 1 F Workout Select Column to Edit Resistance Image 2 G Selec ng a Wor...

Страница 71: ...tance press Check G This brings you back to the previous view Step 2 where you can edit the resistance of other segments Image 3 4 Repeat this process un l your custom workout is complete and then press Save H to save your workout Image 4 Selec ng a Workout Program Random Workout You can increase decrease the difficulty during a workout with the Up Down bu ons A Increasing or decreasing the difficulty...

Страница 72: ...lect User Workout 1 then press the Check B Image 1 2 Press the Check C to setup your workout Image 2 3 Select the Minutes field D and use the up down arrows E to set the dura on Select the Difficulty F refer to chart 1a below for speeds for each difficulty and use the up down arrows E to set the difficulty Then press check G to start workout Image 3 4 Screen as it will appear during workout The difficulty...

Страница 73: ... Pause Stop F Image 4 Dele ng a Created Workout Program 1 Select the User Workout you want to delete and press the check A Image 1 2 From the workout screen press the trash can B Image 2 3 Confirm you wish to delete the program by pressing yes C The screen will return to the Workout List Image 3 Workout List A Random User Workout 1 Image 1 Workout User Workout 1 Image 2 Workout User Workout 1 Imag...

Страница 74: ...nges speed Blink Lights works with all workouts listed in Workout Programs The dura on must be set to 3 minutes or longer for Blink Lights to work Press the Blink Lights line F to turn Blink Lights On Yes or Off No Ramping Ramping 3 Sec B Blink Lights Blink Lights Yes F Start Delay Start Delay C enables you to delay the pumps at the beginning of a workout The delay range is 1 15 seconds D Start Del...

Страница 75: ...t cable and power supply Troubleshooting Stand next to your hot tub or swim spa within 10ft 3m and ensure the power is on Plug in the supplied Ethernet cable to a home router Plug the other end of the cable into the CMS Gateway Ultra Home Module Plug in the power supply to the wall Plug in the power supply into the CMS Gateway Ultra Home Module micro USB power port Steady Red or Blinking Red Spa i...

Страница 76: ...erobic fitness and moderately compe ve sports ac vi es TruSwim provides the ul mate in training for the athlete with the higher range of prop performance 65 100 that no other swim spa dares to match Choose the speed the me of each speed and the total length of your workout gaining the edge you need to be on the top of your game With TruSwim you achieve the highest level of workout in the shortest ...

Страница 77: ...d b a Swim Tether disclaims any liability from and in connec on with the exercise programs provided in this manual on the Swim Tether Website or any other exercise programs u lizing the Swim Tether device including all of its components the belt tether and pole As with any exercise program if at any point during your exercise regime or workout you begin to feel faint dizzy or have physical discomf...

Страница 78: ...er are used in conjunc on with the Swim Tether device Installa on Use Maintenance and Storage Do not leave the Swim Tether device mounted to a pool or spa deck when not in use and never leave the Swim Tether device una ended Installa on of the Swim Tether device deck plate requires a power drill Always take proper safety precau ons and use proper safety equipment when using any power drill especia...

Страница 79: ...l not treat bacteria Total Alkalinity This is a measurement of the water s ability to maintain a proper pH level Total alkalinity is measured in ppm from 0 400 with the op mum reading 100 120 ppm With low alkalinity the pH level will flip easily With a high alkalinity reading it becomes difficult to regulate pH levels This a measurement of acidity ac ve hydrogen in the water pH is not measured in pp...

Страница 80: ...it Leave the cover off and circulate the water for at least 15 minutes a er adding chemicals to effec vely distribute the chemicals and allow odors to escape Ini al Start Up 1 Never use more than 50 so ened water when filling the swim spa It is suggested to use an in line filter on the hose when filling to prevent many minerals from entering the water making balancing and adjus ng the water easier 2...

Страница 81: ...omponents High total alkalinity levels High pH levels High calcium hardness Algae growth low sani zer levels high user load pets rain Overuse of defoamer Red Brown overall imbalance Blue Green high pH level Low calcium hardness Build up of soaps lo ons organic ma er etc pH level imbalance Low sani zer level Low alkalinity pH levels Low alkalinity levels High alkalinity levels High pH and or alkali...

Страница 82: ...rn or lock up completely In the event this happens it will become necessary to remove the handle cap and puck to clean out the diverter valve Follow the steps below to clean out the diverter valve 1 Turn off power to swim spa 2 Remove handle and loosen diverter valve cap If that cap can not be removed by hand you may need to use a wrench Before you place a wrench on the cap cover it first with a cl...

Страница 83: ...ed to many hot cold cycles and the high pressure generated by the powerful jet pump stressing pipes and joints Although the factory has a rigorous tes ng procedure even transporta on from the factory to you can cause vibra on and possible loosening of the joints Should a leak occur remove that appropriate sec on of cabinet wall exposing the leaking area Drain the swim spa to below the leak and con...

Страница 84: ...per jet flow has been achieved If proper jet flow has not been achieved repeat process 9 Open air regulators allowing maximum flow through jets assuring pump opera on 10 Refer to Waterway Neo 2100 Control sec on for hea ng filtra on cycles and func on 11 Adjust water chemistry according to the instruc ons provided in water chemistry guidelines sec on 12 View current water temp on the control panel...

Страница 85: ...d or main skimmer and pump Check water level Push pump bu on s to check if high speed is func oning on a dual speed pump Check to be sure the diverter valve is in center posi on Check for dirty filters and change if necessary 5 No heat Check all steps under part 1 Check temperature se ngs Check for clogged filter element and other restric ons Check water level Check if pump is running 6 No light C...

Страница 86: ... of Maintenance 83 Test GFCI Test GFCI Test GFCI Test GFCI Change All Suc on Fi ngs every 7 years Clean and Drain Swim Spa Change Clean Filter Clean Condi on Cover Miscellaneous Miscellaneous Date Date Date Date Date Date Date ...

Страница 87: ... of Maintenance 84 Test GFCI Test GFCI Test GFCI Test GFCI Change All Suc on Fi ngs every 7 years Clean and Drain Swim Spa Change Clean Filter Clean Condi on Cover Miscellaneous Miscellaneous Date Date Date Date Date Date Date ...

Страница 88: ...sary without no fica on As a manufacturer we stand behind our products in accordance to our wri en limited warranty Your retailer is an independent business operator not employed by the manufacturer PDC Spas Plas c Development Co Inc can not accept responsibility for any representa ons statements or contracts made by any retailer beyond the parameters of our warranty REV 2020 01 ...

Отзывы: