Opera on Systems
Vitality™ Series | SL
‐
Accent™ Control
38
Freeze
Protec on
If the temperature sensors within the heater detect a low enough temperature, then the pump will automa cally ac vate to
provide freeze protec on. The pump will run either con nuously or periodically depending on condi ons.
Clean
‐
up
Cycle
When a pump is turned on by a bu on press, a clean
‐
up cycle begins 30 minutes a er the pump is turned o
ff
or mes out. The
pump and the ozone generator will run for 30 minutes or more, depending on the system.
Temperature
and
Temp
Adjus ng
the
Set
Temperature
The panel has Up and Down bu ons (Temperature bu ons), pressing Up or Down will cause the temperature to
fl
ash. Pressing
a temperature bu on again will adjust the set temperature in the direc on indicated on the bu on. When the LCD stops
fl
ashing,
the spa will heat to the new set temperature when required. Spa temperature can be set between 50
°
F and 104
°
F.
Press
‐
and
‐
Hold
If a Temperature bu on is pressed and held when the temperature is
fl
ashing, the temperature will con nue to change un l the
bu on is released.
NOTE:
Spa
will
not
reach
set
temp
if
unit
is
in
Low
Range.
Check
se ngs
to
be
sure
unit
is
in
High
Range
to
reach
temps
above
80
°
F.
Dual
Temperature
Ranges
This system incorporates two temperature range se ngs with independent set temperatures. The High Range designated in the
display by an “up” arrow, and the Low Range designated in the display by a “down” arrow.
These ranges can be used for various reasons, with a common use being a “ready to use” se ng vs. a “vaca on” se ng. The
Ranges are chosen using the menu structure below. Each range maintains its own set temperature as programmed by the user.
This way, when a range is chosen, the spa will heat to the set temperature associated with that range. For example: High range
might be set between 80°F and 104°F. Low range might be set between 50°F and 99°F. Freeze protec on is ac ve in either range.
1) Press menu key TEMP will be displayed.
2) Use Up or Down arrow to change from High to Low range. A small Up arrow or Down arrow icon will be displayed on the
screen.
NOTE:
Spa
will
not
reach
set
temp
if
unit
is
in
Low
Range.
Check
se ngs
to
be
sure
unit
is
in
High
Range
to
reach
temps
above
80
°
F.
Mode,
Ready
and
Rest
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this func on is known as
the “heater pump.”
READY Mode will circulate water periodically, using Pump Low, in order to maintain a constant water temperature, heat as needed,
and refresh the temperature display. This is known as “polling.”
REST Mode will only allow hea ng during programmed
fi
lter cycles. Since polling does not occur, the temperature display may not
show a current temperature un l the pump has been running for a minute or two.
Ready
‐
in
‐
Rest
Mode
READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It is assumed that the spa is being used and
will heat to set temperature. While pump High can be turned on and o
ff
, pump Low will run un l set temperature is reached, or
1 hour has passed. A er 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and
changing the Mode.