Opera on Systems
Summit™ Series | SX
‐
SmartTouch™ Control
52
Fill
it
Up
Prepara on
and
Filling
Fill the spa to its correct opera ng level. Be sure to open all valves and jets in the plumbing system before
fi
lling to allow as much
air as possible to escape from the plumbing and the control system during the
fi
lling process.
A er turning the power on at the main power panel, the top
‐
side panel will display a company logo screen.
Priming
Mode
A er the ini al start
‐
up sequence, the control will enter Priming Mode and display a Priming Mode screen. Only pump icons
appear on the priming mode screen. During the priming mode, the heater is disabled to allow the priming process to be completed
without the possibility of energizing the heater under low
‐
fl
ow or no
‐
fl
ow condi ons. Nothing comes on automa cally, but the
pump(s) can be energized by selec ng the “Jet” bu ons.
Priming
the
Pumps
As soon as the Priming Mode screen appears on the panel, select the “Jets 1” bu on once to start Pump 1 in low
‐
speed and then
again to switch to high
‐
speed. Also, select the other pumps, to turn them on. The pumps should be running in high
‐
speed to
facilitate priming. If the pumps have not primed a er 2 minutes, and water is not
fl
owing from the jets in the spa, do not allow the
pumps to con nue to run. Turn o
ff
the pumps and repeat the process.
Note: Turning the power o
ff
and back on again will ini ate a new pump priming
session. Some mes momentarily turning the pump o
ff
and on will help it to prime.
Do not do this more than 5 mes. If the pump(s) will not prime, shut o
ff
the power
to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2
minutes. Under NO circumstances should a pump be allowed to run without
priming beyond the end of the 4
‐
5 minute priming mode. Doing so may cause
damage to the pump and cause the system to energize the heater into an overheat
condi on.
Exi ng
Priming
Mode
The system will automa cally enter the normal hea ng and
fi
ltering at the end of the priming mode, which lasts 4
‐
5 minutes.
You can manually exit Priming Mode by pressing the “Back” bu on on the Priming Mode Screen. Note that if you do not manually
exit the priming mode as described above, the priming mode will be automa cally terminated a er 4
‐
5 minutes. Be sure that the
pump(s) have been primed by this me.
Once the system has exited Priming Mode, the top
‐
side panel will display the Main Screen, but the display will not show the water
temperature yet, as shown below. This is because the system requires approximately 1 minute of water
fl
owing through the heater
to determine the water temperature and display it.
–
–
–
–°F
–
–
–
–°C
WARNING:
R
. PDC Spas, PDC Interna onal assumes no responsibility for personal injury
or property damage sustained by or through the use of this product. When installing and using this equipment
basic safety precau ons should always be taken to reduce risk of electrical shock, ensure safe usage, and safeguard the user’s health.