A good general rule is to visually inspect your swim spa and equipment area frequently. If anything looks
broken, worn, or incorrect, contact your electrician or spa retailer. A simple repair may prevent an injury or more
serious problems requiring expensive repairs. If your swim spa is not opera ng, check the following:
1.
Nothing
on
the
swim
spa
operates
Check power source G.F.C.I. breaker. (or equivalent)
Check to assure spa has dedicated circuit.
Check the “test” and “reset” bu ons on G.F.C.I. (or equivalent)
Check
internal
fuses
.
Review control panel for any error code. Refer to that sec on of this manual.
2.
Hydraulic
propulsion
not
opera ng
Low oil. Contact service center prior to opera ng system..
3.
Pump
does
not
work
Check all items above.
Check
fi
lter; clean or replace cartridge.
Check
for
blockages
(restric ons) at suc ons, skimmer and pump.
Push
“pump”
bu on(s) to check if high speed is func oning, on a dual
‐
speed pump.
4.
Inadequate
jet
ac on
Make sure jets are turned on.
Make sure air controls are open.
Check
for
restric ons (blockages) in jets and/or main skimmer and pump.
Check
water
level.
Push
“pump”
bu on(s) to check if high speed is func oning on a dual
‐
speed pump.
Check to be sure the diverter valve is in center posi on.
Check
for
dirty
fi
lters and change if necessary.
5.
No
heat
Check all steps under part “1”.
Check
temperature
se ngs.
Check
for
clogged
fi
lter element and other restric ons.
Check
water
level.
Check if pump is running.
6.
No
light
Check
“light”
bu on.
Check G.F.C.I. (or equivalent) “test” and “reset” bu ons.
7.
Water
is
cloudy
Increase
circula on cycle.
Test
water
chemistry.
Clean/replace
fi
lter cartridge.
8.
GFCI
or
equivalent
is
tripping
A ground fault circuit interrupter (GFCI) is required by the Na onal Electric Code for your protec on.
The tripping of the GFCI may be caused by a component on the spa or by an electrical problem.
Electrical problems include although are not limited to, a faulty GFCI breaker, spa component, power
fl
uctua ons, or improper wiring. If this new electrical service and GFCI installa on, an instantly
tripping GFCI may likely be caused by improper wiring of the neutral from the GFCI to the spa. Contact
a
quali
fi
ed technician to rec fy the problem.
If
above
checks
do
not
solve
the
problem,
contact
a
quali
fi
ed
service
technician.
Basic Troubleshoo ng