Opera on Systems
Vitality™ Series | SL
‐
Accent™ Control
42
Heater
may
be
Dry
(dr)*
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any bu on to reset the
heater start
‐
up. See “Flow Related Checks” below.
Heater
is
Dry*
There is not enough water in the heater to start it. The spa is shut down. A er the problem has been resolved, you must press any
bu on to reset and restart heater start up. See “Flow Related Checks” below.
Heater
is
too
Hot
(OHH)*
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut down. You must clear the message
when water is below 108°f (42.2°C). See “Flow Related Checks” below.
A
Reset
Message
may
appear
with
other
Messages
Some errors may require power to be removed and restored.
Flow
‐
Related
Checks
Check for low water level, suc on
fl
ow restric ons, closed valves, trapped air, too many closed jets and pump prime. On some
systems, even when spa is shut down by an error condi on, some equipment may occasionally turn on to con nue monitoring
temperature or if freeze protec on is needed.
Sensor
‐
Related
Sensors
Balance
is
Poor
The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service.
Sensors
Balance
is
Poor*
The temperature sensors ARE out of sync. The fault above has been established for at least 1 hour. Call for Service.
Sensor
A
Fault,
Sensor
B
Fault
–
Sensor
A,
Sensor
B
A temperature sensor or sensor circuit has failed. Call for Service.