background image

 

 

 

 

PROGRAMMING INSTRUCTIONS 

 

   

1.  Illustration to buttons 

F

AM

PM

LIGHT

OZONE

OFF

ON

PUMP2

BLOWER

PUMP1

PUMP3

SET

LOCKED

HEAT

C

F/

OZONE

PUMP2

HEAT

PUMP3

ON/OFF

CD

MEM

CLOSE

HOUR

OPEN

MIN

SET

VOL+

TEMP

 

Fig

1

Sketch map of big massage bathtub 

 

 

 

MIN

  Radio channel up / Minute 

ON/OFF

  power 

On/ Off or mode shift 

HOUR

radio channel down/ Hour 

CD

RADIO

radio on/ off or CD shift 

SET

VOL+

volume up/ time setting shift   

C

F/

blower on/ off or

 

  & 

  Shift 

OPEN

volume down/ open memory channel   

LED & fiber optic lights on/ off 

MEM

radio channel memory/ lock channel 

whirlpool    pump 1&2    on/ off 

CLOSE

select radio channel / close channel 

PUMP2

  waterfall & column pump on/ off 

OZONE

ozonizer    on/off 

PUMP3

  whirlpool  pump  3  &  circulation  pump   

on/ off. 

HEAT

  preheat    on/ off or preset 

TEMP

  Temperature setting 

Note

 

1. 

All the functions listed on the key in blue letter only works on the “off” model. 

2. 

PUMP2

function is not available on SPA-329,312, which model without water column and waterfall.

 

 

Содержание SPA-329

Страница 1: ... volume up time setting shift C F blower on off or Shift OPEN volume down open memory channel LED fiber optic lights on off MEM radio channel memory lock channel whirlpool pump 1 2 on off CLOSE select radio channel close channel PUMP2 waterfall column pump on off OZONE ozonizer on off PUMP3 whirlpool pump 3 circulation pump on off HEAT preheat on off or preset TEMP Temperature setting Note 1 All t...

Страница 2: ...and LCD screen on the panel will be displaying time and current water temperature and the radio channel will be display Under the situation it indicates the spa system is on off status the preheat and circulation cleaning functions are turned off If the water temperature sensor is broken circuit the screen will display E1 if the water temperature sensor is short circuit the screen will display FF ...

Страница 3: ...ulation cleaning working status will be displaying on the LCD screen When it works or can not see from the screen If the signal is displaying on the screen it indicates the circulation cleaning is on and the signal is disappeared it indicates the circulation cleaning is off See following Fig 5 6 AM AM Fig 5 Circulation cleaning off Fig 6 Circulation cleaning on All the setting steps of circulation...

Страница 4: ...IN key one time the working time will add 5 minute The maximum working time of circulation time is19 hours 55 minutes this time can be adjusted according to the user After setting the working time of Circulation cleaning and move on to set the ozone working in synchronization 4 And then press the SET VOL key again to set startup the ozonizer working in synchronization at this time the OZONE signal...

Страница 5: ...ing signal at this status 1 Press HEAT to enter into the preheating setting model and the screen will flash the ON OFF signal 2 Press OPEN can start the preheating setting If press CLOSE key or without any pressing in 6 seconds the preheating will be shut down and the system will quit out the setting model automatically the signal on the screen will be from ON OFF turn into ON won t flash just dis...

Страница 6: ... add 10 minute Pressing the HOUR key each time the working time will add one hours The maximum working time of preheating is 19 hours 50 minutes After setting the working time of preheating and move on to set water temperature 4 And then press the SET VOL key to set the water temperature at this time the SET signal will be flashing on the screen Pressing the TEMP key to increase the temperature lo...

Страница 7: ...ress the HEAT key or ON OFF key to quit out the preheating program turn off the heater 7 Circulation cleaning working status On the off status when time reach the set time of circulation cleaning and the signal of circulation cleaning is displaying on the screen meanwhile the tub is filled with enough water The circulation cleaning program will be start up automatically the circulation pump and oz...

Страница 8: ... will increase continually till 45 When the degree is reach 40 to press the TEMP key the degree will be 18 again The adjustable temperature degrees is 18 45 10 Operation of Radio CD AM PUMP3 Fig 11 Radio frequency is 105 2 MHZ Save the present frequency to channel 3 Save channel or Exchange the frequency form channel 3 to the present Searching channel Ⅰ Key AUDIO CD is the ON OFF key for radio and...

Страница 9: ...n begin to works for 15 minutes and stop for one hour and 45 minutes 13 Operation of lights To press the key to turn on or off the underwater light and fiber optic lights All the lights can be turned on on any mode so to turn on is way to test if the spa system is connect with power successfully or not 14 Operation of constant water temperature 1 To press the HEAT key two times the first time is t...

Страница 10: ...ex Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x 1 water pump AC220V 2HP x 2 water pump AC220V 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 2 Ozone AC12V 15W x 1 water pump AC220v 0 35HP x 1 Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker 5 Warning Information a Means for disconnection must be incorporated in the fixed wiring in ac...

Страница 11: ...the wiring rules for example specifying that parts are installed in the correct zone and that equipotential bonding is carried out WARNING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by...

Страница 12: ...12 ...