Opera on Systems
Vitality™ Series | SL
‐
Accent™ Control
39
Show
and
Set
Time
of
Day
Se ng the me
‐
of
‐
day can be important for determining
fi
ltra on mes and other background features. When in the TIME menu,
SET TIME will
fl
ash on the display if no me
‐
of
‐
day is set in the memory.
Se ng Time:
1) Repeatedly press menu key un l set me or me appears on screen.
2) Press up or down arrow to adjust hour.
3) Press light key to switch to minutes.
4) Press up or down key to adjust minutes.
5) Press light key to exit.
If power is interrupted to the system, Time
‐
of
‐
Day is not stored. The system will s ll operate and all other user se ngs will be
stored. If
fi
lter cycles are required to run at a par cular me of day, rese ng the clock will return the
fi
lter mes to the actual
programmed periods.
When the system starts up, it defaults to 12:00 Noon, so another way to get
fi
lter mes back to normal is to start up the spa at
noon on any given day. SET TIME will s ll
fl
ash in the TIME Menu un l the me is actually set, but since the spa started at noon,
the
fi
lter cycles will run as programmed.
Restric ng
The control can be restricted to prevent unwanted use or temperature adjustments.
Locking the panel prevents the controller from being used, but all automa c func ons are s ll ac ve.
Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed se ngs
cannot be adjusted.
Temperature Lock allows access to a reduced selec on of menu items. These include Set Temperature, FLIP, LOCK, UTIL, INFO and
FALT LOG.
Set Restric ng:
1) Press menu key un l Lock appears.
2) Press up arrow for temp lock.
3) Press up arrow again to ac vate temp lock or light key to switch to panel lock.
4) Press up arrow again to ac vate panel lock.
Unlocking
T
his Unlock sequence may be used from any screen that may be displayed on a restricted panel.
NOTE: If the panel has both an UP and a Down bu on, the ONLY bu on that will work in the Unlock Sequence is the UP bu on.
Set Unlocking:
1) Press and hold up arrow.
2) While pressing and holding up arrow press and release light key twice.
Hold
Hold Mode is used to disable the pumps during service func ons like cleaning or replacing the
fi
lter. Hold Mode will last for 1 hour
unless the mode is exited manually.
Set Hold:
1) Press menu key repeatedly un l hold is displayed.
2) Press
up
arrow
to enter hold.
3) Press down arrow to exit hold.