Opera on Systems
Synergy™ Series | FX
‐
ProView™ Control
49
Addi onal
Se ngs
Hold
Mode
Hold Mode is used to disable the pumps during service func ons like cleaning or replacing the
fi
lter. Hold Mode will last for 1 hour
unless the mode is exited manually. If spa service will require more than an hour, it is best to simply shut down power to the spa.
U li es
The U li es Menu and Preferences selec ons are to be accessed only by quali
fi
ed service techs.
Temp
Display:
Change the temperature between Fahrenheit and Celsius
Time
Display:
Change the clock between 12 hr. and 24 hr. display.
Reminders:
Turn the reminder messages (like “Clean Filter”) On or O
ff
.
Cleanup:
Cleanup Cycle Dura on is not always enabled, so it may not appear. When it is available,
set the length of me Pump 1 will run a er each use. 0
‐
4 hours are available.
Color:
Pressing the Select Bu on when Color is highlighted will cycle through 5 background colors available in the control.
Language:
Change the language displayed on the panel.
Clean
‐
up
Cycle
(op onal)
When a pump is turned on by a bu on press, a clean
‐
up cycle begins 30 minutes a er the pump is turned o
ff
or mes out.
The pump and the ozone generator will run for 30 minutes or more, depending on the system.
Freeze
Protec on
If the temperature sensors within the heater detect a low enough temperature, then the water devices automa cally ac vate to
provide freeze protec on. The water devices will run either con nuously or periodically depending on condi ons.
GFCI
Test
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) is an important safety device and is required
equipment on a spa installa on.
CE registered systems do not have an RCD Test Feature due to the nature of the electrical service. The end
‐
user must be trained
how to properly test and reset the RCD.
It
is
mandatory
to
verify
proper
installa on
and
func on
of
the
GFCI
or
RCD.
Users
/
owners
are
to
manually
test
this
safety
device
prior
to
each
use.
Should
the
device
not
func on
properly,
shut
the
spa
o
ff
at
the
breaker
and
contact
service
tech.
General
Most messages and alerts will appear at the bo om of the normally used screens. Several alerts and messages may be displayed in
a sequence. Some messages can be reset from the panel. Messages that can be reset will appear with a “right arrow” at the end of
the message. This message can be selected by naviga ng to it at pressing the Select bu on.
Water
Temperature
is
Unknown
A er the pump has been running for 1 minute, the temperature will be displayed.
–
–
–°F
–
–
–°C
NOTE: The icon on the main
screen will glow red when the heater is ac vated. The Jets 1 icon will also glow red while in low speed and the heater is ac vated.
Possible
freezing
condi on
A poten al freeze condi on has been detected. All water devices are ac vated. In some cases, pumps may turn on and o
ff
and the
heater may operate during Freeze Protec on. This is an opera onal message, not an error indica on.