User Manual For CYCLONE
FX
Programmers
49
7.4.3.1.1 Launch Programming
This allows the user to execute the programming function. The Cyclone will program the target
device, if able, using the currently selected programming image. This is functionally equivalent to
pressing the Start button.
7.4.3.1.2 Verify Data In Target
Performs a verify function on the data that has been programmed into the target device.
7.4.3.1.3 Toggle Power
Toggles the target power and makes sure all ports are driven to debug mode level.
7.4.3.1.4 Power Cycle Device To Run User Code
Toggles the target power and maintains tri-state mode for all signals.
7.4.3.1.5 Validate Image CRC32
Allows the user to perform a CRC32 validation on the currently selected programming image.
7.4.3.2
Set Image Validation
Allows the user to choose between two validation settings: 1) validate the image each time the
Start button is pressed, or 2) do not validate the image.
7.4.3.3
Modify Next Serial Number
Presents options that display the current serial number and allow the user to increase or decrease
the next serial number. Tap “Current Image ID Selected” to view/choose the desired programming
image; tap “Current Alg ID Selected” to view/choose the desired programming algorithm; use
“Current CS ID Selected” to view/choose the desired Choose Serial file. The adjustment buttons
will display “Increase Not Allowed” and “Decrease Not Allowed” if the image/algorithm/CS files that
the user has selected to do not allow for this operation.
7.4.3.4
Show Current Image Stats
Displays current statistics, if any, for Image Programmed Count & Maximum Allowed, Errors
Logged & Maximum Allowed, and Date Range Allowed. These limits can be set in the Image
Creation Utility.
Note:
When
Current Image Stats
is displayed as a home screen item, only Image Programmed
Count & Maximum Allowed are displayed on the home screen.