User Manual For CYCLONE
FX
Programmers
6
Figure 3-2: CYCLONE
FX
Right Side View
3.5
Cyclone System Power
The
CYCLONE
FX
programmer requires a regulated 6V DC Center Positive power supply with
2.5/5.5mm female plug. Cyclones derive power from the Power Jack located on the right end of the
unit. The location of Cyclone System Power is shown in
.
3.6
RS232 Communication (Serial Port)
The
CYCLONE
FX
provides a DB9 Female connector to communicate with a host computer
through the RS232 communication (115200 Baud, 8 Data bits, No parity, 1 Stop bit). The location
of the Serial Port is shown in
3.7
Ethernet Communication
The
CYCLONE
FX
provides a standard RJ45 socket to communicate with a host computer
through the Ethernet Port (10/100 BaseT). The location of the Ethernet Port is shown in
3.8
USB Communications
The
CYCLONE
FX
provides a USB connector for Universal Serial Bus communications between
the Cyclone and the host computer. The
CYCLONE
FX
is a USB 2.0
Full-Speed
compliant device.
The location of the USB Port is shown in
3.9
Electromechanical Relays
Inside the
CYCLONE
FX
programmer, two electromechanical relays are used to cycle target
power. The specifications of the relays are as following:
Maximum switched power:
30W or 125 VA
Maximum switched current:
1A
Maximum switched voltage:
150VDC or 300VAC
UL Rating:
1A at 30 VDC
1A at 125 VAC
PEmicro only recommends switching DC voltages up to 24 Volts.