User Manual For CYCLONE
FX
Programmers
29
5.2.1
Select Programming Image
Displays a list of the available programming images so that the user may select one for
programming. Images in the Cyclone’s internal memory are preceded by the designation
“IN”
and
numbered sequentially, i.e.,
IN1:
first image name
,
IN2:
second image name
. If the SDHC port of
the Cyclone contains a memory card, any programming images that reside on the SD card will be
preceded by the designation
“EX”
in similar fashion.
You may tap the appropriate image to select it. The image name shown is the one specified in the
Cyclone Configuration Utility when saving the image to the Cyclone/SD card.
5.2.2
Current Image Options
This menu presents options that allow the user to select or configure programming images on the
CYCLONE
FX
.
5.2.2.1
Execute Image Function
Execute Specific SAP Function presents four Stand-Alone Programming functions that you may
execute by tapping the function that you wish to execute:
5.2.2.1.1 Launch Programming
This allows the user to execute the programming function. The
CYCLONE
FX
will program the
target device, if able, using the currently selected programming image. This is functionally
equivalent to pressing the Start button.
5.2.2.1.2 Verify Data In Target
Performs a verify function on the data that has been programmed into the target device.
5.2.2.1.3 Toggle Power
Toggles the target power and makes sure all ports are driven to debug mode level.
5.2.2.1.4 Power Cycle Device To Run User Code
Toggles the target power and maintains tri-state mode for all signals.
5.2.2.1.5 Validate Image CRC32
Allows the user to perform a CRC32 validation on the currently selected programming image.
5.2.2.1.6 Launch Image Programming
Launches the selected programming image. Replaces the hardware Start Button.
5.2.2.2
Set Image Validation
Allows the user to choose between two validation settings: 1) validate the image each time the
Start button is pressed, or 2) do not validate the image.
5.2.2.3
Modify Next Serial Number
Presents options that display the current serial number and allow the user to increase or decrease
the next serial number. Tap “Current Image ID Selected” to view/choose the desired programming
image; tap “Current Alg ID Selected” to view/choose the desired programming algorithm; use
“Current CS ID Selected” to view/choose the desired Choose Serial file. The adjustment buttons
will display “Increase Not Allowed” and “Decrease Not Allowed” if the image/algorithm/CS files that
the user has selected to do not allow for this operation.
5.2.2.4
Show Current Image Stats
(FX Only)
Displays current statistics, if any, for Image Programmed Count & Maximum Allowed, Errors
Logged & Maximum Allowed, and Date Range Allowed. These limits can be set in the Image
Creation Utility when using the
CYCLONE
FX
.