8
8
When using a receiver that has been installed separately into the ceiling, use the
enclosed fittings for installing to a ceiling.
(1) Remove the metal plate of the receiver by slipping a flathead screwdriver or the like
into the cut-out on the bottom.
(2) Cut out a hole in the ceiling to match the dimensions of the enclosed template.
(95 × 51 mm)
(3) Pass the wiring through the enclosed installation metal fitting and put it into the hole.
(Fig. 8-6)
(4) Bend parts A and B of the metal fitting so they hold onto the ceiling firmly. (Fig. 8-7)
(5) Connect the receiver’s wiring (2 cores) with the wiring from the indoor unit.
(Refer to the chapter on wiring the receiver.) When wiring receivers, be sure to
double-check the terminal numbers of the indoor unit before connecting them so
there are no mistakes in the wiring. (Damage will occur if high voltage [e.g. supply
voltage] is applied.)
(6) Adjust the enclosed spacers so they are several millimeters thicker than the ceiling
material and hold the receiver in place temporarily with the 2 enclosed machine
screws. (M4 × 40)
(7) Bend parts A and B back so they fit in the opening and are in the gap between the
surface of the ceiling and the receiver; then tighten the screws. Do not use too much
force when tightening the screws. Doing so may warp or damage the case. Move the
receiver by hand and check that it can move just a little. (Fig. 8-8)
(8) Attach the face plate.
6. Wiring the Receiver
• Use wiring of 0.5 mm
2
to 2 mm
2
for field supply.
• Use a total wire length of no more than 400 m.
Polarity does not matter.
If it is to be used as an embedded model ;
Wiring Diagram
If it is to be used as an exposed model :
Wiring Diagram
• Use remote control cord (sold separately) f
or wiring a separately installed receiver.
(1)
(2)
For instructions on how to install a remote control cord (sold separately), refer to the chapter on Using as an
Embedded Model in Installing Separate Receivers.
If a remote control cord (sold separately) is to be used, refer to the Mounting Instructions attached to the
remote control cord.
1.
2.
3.
Strip the wire to be connected of its sheathing for 14 mm.
Twist the two wires together and crimp the enclosed wire joint.
If a special crimping tool is not used, or if the connection is made using solder,
wrap the joint with insulating tape.
-+
-+
Fig. 8-6
Fig. 8-7
Fig. 8-8
Part A
Part B
Enclosed wire joints (2, white)
Receiver wires
(Field supply)
Receiver wires
(Field supply)
Wire joint CE-1
(Enclosed)
White
Black
1
2
1
2
Terminal strip for wiring the
remote control of the indoor
unit
Connections
Receiver
Receiver wires
(Field supply)
Wires from the
receiver unit
1
2
1
2
White
Black
Terminal strip for wiring the
remote control of the indoor
unit
Receiver
Remote Control Cord
(Sold Separately)
8-13
SM830194-04_Single_BigPAC.indb 13
2014/10/31 13:30:52
Содержание S-200PE1E8
Страница 88: ...1 82 MEMO ...
Страница 112: ...3 2 3 3 1 Outdoor Units Electric Wiring Diagram U 200PE1E8 U 250PE1E8 ...
Страница 113: ...3 3 3 Schematic Diagram U 200PE1E8 U 250PE1E8 ...
Страница 114: ...3 4 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE2E5 S 250PE2E5 Electric Wiring Diagram ...
Страница 115: ...3 5 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Electric Wiring Diagram ...
Страница 116: ...3 6 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8A Schematic Diagram ...
Страница 117: ...3 7 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Electric Wiring Diagram ...
Страница 118: ...3 8 3 3 2 Indoor Units High Static Pressure Ducted Type S 200PE1E8 Schematic Diagram ...
Страница 119: ...3 9 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Electric Wiring Diagram ...
Страница 120: ...3 10 3 3 2 Indoor Units High Static Pressure Ducted Type S 250PE1E8 Schematic Diagram ...
Страница 129: ...4 9 4 4 3 Outdoor Unit Filter PCB FIL C906VH8 ...
Страница 130: ...4 10 4 4 4 Outdoor Unit HIC Board HIC C906VH8 ...
Страница 136: ... MEMO 4 16 ...
Страница 154: ... MEMO 5 18 ...
Страница 164: ... MEMO 6 10 ...
Страница 180: ... MEMO 7 16 ...
Страница 197: ...201411 ...