Install HBA SAS Cables
■
“Returning a Server to Operation” on page 235
Install HBA SAS Cables
Replacing the cable assembly is a cold-service procedure that must be performed by qualified
service personnel. The server must be completely powered down before performing this
procedure.
1.
Carefully guide HBA SAS cables through the server.
2.
If installing replacement cables, fold the new cables 90-degrees at the first bend
coming out of the connector.
Note -
This angle positions the cables accurately without placing stress on the connectors and
the HBA card. Be careful not to stress or bend the HBA card while routing the cables.
Servicing the Cables