Remove a PCIe Card
See
“Remove a PCIe Card” on page 174
7.
If you are unable to determine if a PCIe card is faulty, seek further information.
See
“Detecting and Managing Faults” on page 25
Related Information
■
“PCIe Card Configurations” on page 170
■
“Remove a PCIe Card” on page 174
■
“Verify a PCIe Card” on page 177
Remove a PCIe Card
Removing a PCIe card is a cold-service operation. You must power off the server before you
remove the PCIe card.
Note -
This procedure is the same for removing a filler.
1.
Determine which PCIe card to remove.
See
“Locate a Faulty PCIe Card” on page 172
2.
Prepare for service.
See
“Preparing for Service” on page 43
3.
Remove the server to obtain access to internal components.
See
“Accessing Internal Components” on page 55
174
Netra SPARC S7-2 Server Service Manual • February 2017
Содержание Netra SPARC S7-2
Страница 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Страница 2: ......
Страница 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Страница 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...