Digital Operator Functions
6-
137
Select READ Permitted
Prevent overwriting the data stored in EEPROM in the Digital Operator by mistake. With o3-02 set to 0, if you
set o3-01 to 1, and perform the write operation, PrE will be displayed on the Digital Operator, and the write
operation will be stopped.
Writing Constant Set Values Stored in the Digital Operator to the Inverter (COPY)
To write constant set values stored in the Digital Operator to the Inverter, make the settings using the follow-
ing method.
Tried to write constants to EEPROM on the Digital Operator, but unable to perform write
operation.
Table 6.2 COPY Function Procedure
Step
No.
Digital Operator Display
Explanation
1
Press the MENU Key, and select advanced programming mode.
2
Press the DATA/ENTER Key, and select the constants monitor display.
3
Display o3-01 (Copy Function Selection) using the Increment Key and Decrement
Key.
4
Press the DATA/ENTER Key, and select the constants setting display.
5
Change the set value to 2 using the Increment Key.
6
Set the changed data using the DATA/ENTER Key. The COPY function will start.
7
If the COPY function ends normally, End is displayed on the Digital Operator.
8
The display returns to o3-01 when a key is pressed.
Error Display
Meaning
RDE
DATA ERROR
** Main Menu **
-ADV-
Programming
Initialization
-ADV-
A1
- 00=1
Select Language
COPY Function
-ADV-
o3
- 01=0
Copy Funtion Sel
Copy Funtion Sel
-ADV-
o3-01=
0
COPY SELECT
*0*
Copy Funtion Sel
-ADV-
o3-01=
2
OP
→
INV WRITE
*0*
COPY
-ADV-
OP
→
INV COPYING
COPY
-ADV-
COPY COMPLETE
Copy Funtion Sel
-ADV-
o3 -
01
=0
COPY SELECT
*0*
Содержание VARISPEED G7 -
Страница 3: ......
Страница 11: ...viii...
Страница 33: ...1 16...
Страница 105: ...4 20...
Страница 349: ...6 154...
Страница 375: ...7 26...
Страница 413: ...10 24...
Страница 417: ......