Deceleration to Stop
If the stop command is input (i.e., the run command is turned OFF) when b1-03 is set to 0, the motor deceler-
ates to a stop according to the deceleration time that has been set. (Factory setting: C1-02 (Deceleration Time
1))
If the output frequency when decelerating to a stop falls below b2-01, the DC injection brake will be applied
using the DC current set in b2-02 only for the time set in b2-04.
For deceleration time settings, refer to
page 6-16 Setting Acceleration and Deceleration Times
.
Fig 6.11 Deceleration to Stop
b2-03
DC injec-
tion brak-
ing time at
start
Used to set the time to perform DC injec-
tion braking at start in units of 1 second.
Used to stop coasting motor and restart it.
When the set value is 0, DC injection
braking at start is not performed.
0.00
to
10.00
0.00 s
No
A
A
A
A
A
DCInj
Time@Start
b2-04
DC injec-
tion brak-
ing time at
stop
Used to set the time to perform DC injec-
tion braking at stop in units of 1 second.
Used to prevent coasting after the stop
command is input. When the set value is
0.00, DC injection braking at stop is not
performed.
0.00
to
10.00
0.50 s
No
A
A
A
A
A
DCInj
Time@Stop
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Display
V/f
V/f
with
PG
Open-
loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
Decelerates to stop at
deceleration time
Output frequency
Run command
ON
OFF
DC injection brake time
when stopping (b2-04)
DC injection brake