User Constant Tables
5-
31
d6-05
A
φ
R time
constant
Set the factor to multiple
times the secondary circuit
time constant of the motor to
achieve the A
φ
R time
constant.
A
φ
R time constant =
Secondary circuit time
constant x d6-05
A
φ
R will not function when
d6-05 is 0. If d6-05 is not 0,
the lower limit of the value
will be internally adjusted to
200 ms in the Inverter.
0.00 to
10.00
1.00
No
No
No
No
No
A
2A4H
-
A PHI R
Filter
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2