![Omron SYSMAC CJ1W-SCU21-V1 Скачать руководство пользователя страница 725](http://html1.mh-extra.com/html/omron/sysmac-cj1w-scu21-v1/sysmac-cj1w-scu21-v1_operation-manual_743586725.webp)
696
V600/V620 ID Controller Protocol
Appendix P
Read (ASCII/1) (Sequence No. 500 (Hex 01F4))
This sequence is used when the number of Heads to be read from the Carrier is 1.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Note
Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the
receive data words, as shown in the following diagram.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0005 (fixed)
+1
Unit No. (2 digits BCD)
00 to 07 (CD1D)
00 to 15 (CA
@
A)
+2
R/W Head channel
(CH) No. (1 digit BCD)
R/W Head CH 1 designation: 1
R/W Head CH 2 designation: 2
The CD1D must be set to 1.
+3
Leading address No.
(4 digits Hex)
0000 to FFFF
+4
Read bytes
(2 digits Hex)
01 to F4 (1 to 244 bytes)
Offset
Contents (data format)
Data
+0
Number of receive data
words (4 digits Hex)
0002 to 007B (2 to 123 decimal)
+1 to +122
Read data (ASCII)
Number of read bytes stored in ASCII
First word of send
data
Number of send data words
+0
+1
+2
+3
+4
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
(Undefined)
Read bytes
Receive data
storage words
Number of receive data words
+0
+1
+2
+122
Read data
~
~
Read data
Read data
Data Carrier
Receive data storage words
Example for 5 bytes
Each byte (address) in the Data
Carrier contains the code for one
ASCII character.
+0
+1
+2
+3
+4
+0
+1
+2
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...