442
Mitsubishi Computer Link Master (A-compatible 1C Frame, Model 1)
Appendix E
Command Response Formats
Note
In the following diagrams “hex” indicates hexadecimal values. Values in quotation marks, such as “00”
indicate ASCII characters.
Command Frame
Response Frame
• Normal Response Type 1
• Normal Response Type 2
• Error Response
Command Frame Contents
ENQ
05 hex
2 bytes
Checksum
PLC
No.
Characters (text)
@@
hex
@@
hex
@@
hex
@@
hex
1 byte
2 bytes
2 bytes
2 bytes
1 byte
30 hex
Station
No.
Command
code
Transmission
delay
STX
PLC
No.
Characters (text)
ETX
Checksum
1 byte
1 byte
1 byte
1 byte
1 byte
03 hex
1 byte
1 byte
1 byte
02 hex
@@
hex
@@
hex
@@
hex
@@
hex
Station
No.
ACK
PLC
No.
06 hex
1 byte
1 byte
1 byte
1 byte
@@
hex
@@
hex
@@
hex
@@
hex
1 byte
Station
No.
2 bytes
02 hex
1 byte
1 byte
1 byte
1 byte
@@
hex
@@
hex
@@
hex
@@
hex
1 byte
NAK
PLC
No.
Error code
Station
No.
Item
Contents
Control code
ENQ (05 hex) for A-compatible 1C frames, model 1.
Station No.
This number distinguishes the remote destination Computer Link Module.
Setting range: 00 to 1 F hex (0 to 31 decimal), or FF hex (255 decimal) using global function. Set in
2 digits hexadecimal.
PLC No.
This number distinguishes the remote destination Sequencer CPU Module. Set in 2 digits hexadeci-
mal
Accessing Sequencer CPU Module (local station) that is directly connected to the host using serial
communications: All FF hex (255 decimal)
Accessing Sequencer CPU Module (local station) on the MELSECNET or Ethernet network that is
not directly connected to the host using serial communications:01 to 40 hex (1 to 64 decimal) or 00
hex (0 decimal).
Command code
Specify the processing command to read/write device memory and execute remote RUN/STOP of
the Mitsubishi Sequencer CPU Module at the remote destination.
Send delay
This is the delay until a response is returned from the remote destination Computer Link Module.
The send delay is not supported by this protocol, and 0 hex (0 ms) is set in the command frame
automatically.
Device type
Set the following device type characters in ASCII.
All characters except T/C: X, Y, M, L, S, B, F, M, D, W, R, D
T/C characters: TS (contact), TC (coil), CS (contact), CC (coil), TN (PV), CN (PV)
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...