K Digital Controller Read Protocol
Appendix F
Read MV at Stop Time and at PV Error (Sequence No.013 (Hex
000D))
Reads the MV at stop time and at PV error and stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Read MV Limits (Sequence No. 014 (Hex 000E))
Reads the MV upper limit, MV lower limit, and MV change rate limit and stores the results in the specified
words.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0002 (fixed)
+1
Unit No. (2 digits BCD)
00 to 31
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0003
+1
MV at stop time (4 digits BCD)
F050 to 1050
F indicates a negative value.
A050 to 1050 for heating/cooling control
A indicates a negative value.
+2
MV at PV error (4 digits BCD)
F050 to 1050
F indicates a negative value.
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0002 (fixed)
+1
Unit No. (2 digits BCD)
00 to 31
Offset
Contents (data format)
Data
+0
Number of receive data words
(4 digits Hex)
0004
+1
MV upper limit (4 digits BCD)
MV lower limit + 1 to 1050
0000 to 1050 for heating/cooling control
First word of
send data
Number of send data words
+0
+1
(Undefined)
Unit No.
Receive data
storage words
Number of receive data words
+0
+1
+2
MV at stop time
MV at PV error
First word of
send data
Number of send data words
+0
+1
(Undefined)
Unit No.
Receive data
storage words
Number of receive data words
+0
+1
+2
+3
MV upper limit
MV lower limit
MV change rate limit
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...