238
Communications Frames
Section 6-8
Further, to write the CompoWay/F command to the command storage area
using CMND(490) in frame order (without creating empty bytes), the SID com-
ponent of the CompoWay/F command requires 1 byte of ASCII as 30 hex, so
the subsequent components (s+3 and afterwards) must be set in one byte
each.
Response Frame
6-8-2
Modbus-RTU
Command Frame
Note
The silent interval in the Modbus-RTU frame is automatically generated by the
Serial Communications Board/Unit.
Frame before Conversion
CompoWay/F
(See note.)
FINS end code
FINS command
FINS header
Frame after Conversion
CompoWay/F
STX
(02 hex)
Node No.
(
×
10
1
)
(
×
10
2
)
(ASCII
code
4 bytes)
Remote
network
address
(DNA)
Remote
node
address
(DA1)
SRC
MRC
MRES
SRES
Serial
port
allocated
address
00 hex
Serial
port unit
address
03
28
Node No.
(
×
10
1
)
(
×
10
2
)
(ASCII code
2 bytes)
Sub-
address
"00"
(ASCII code
3030 hex)
etc.
Command
(MRC,
SRC)
(ASCII
code
4 bytes)
End code
(ASCII
code
2 bytes)
Response
(MRES,
SRES)
(ASCII
code
4 bytes)
Text
(ASCII
code)
Sub-
address
"00"
(ASCII
code
3030
hex) etc.
Command
(MRC,
SRC)
(ASCII
code
8 bytes)
Text
(ASCII
code)
Response
(MRES,
SRES)
(ASCII
code
8 bytes)
ETX
(03 hex)
BCC
End code
(ASCII
code
8 bytes)
Remote
unit ad-
dress
(DA2)
etc.
User-
speci-
fied
User-
speci-
fied
Frame before Conversion
FINS header
Frame after Conversion
FINS command
Remote
network
address
(DNA)
Remote
node
address
(DA1)
Remote
unit
address
(DA2)
Etc.
MRC
SRC
Serial port
allocated
address
00 hex
Serial
port
unit
address
28
04
or local
network
address
or local
network
node
address
Modbus-RTU frame
Start (silent
interval of
3.5
characters)
(See note.)
Slave
address
(1 byte)
FUNCTION
code
(1 byte)
Communications data
(n bytes)
Error
check
CRC
(1 byte)
End (silent
interval of
3.5
characters)
(See note.)
Modbus-RTU
(command section only)
Slave
address
(1 byte)
FUNCTION
code(1 byte)
Communications data
(n bytes)
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...