460
Mitsubishi Computer Link Master (A-compatible 1C Frame, Model 1)
Appendix E
Device Memory Batch Read as Bit Data (All Device Types Except T/C)
(Sequence No. 814 (Hex 032E)) (Command Code: JR)
This sequence reads the bit data for the number of device points starting from the specified device address for
the specified device type (except T, C) in the Mitsubishi Computer Link Module with the specified station num-
ber (and the PLC number that follows), converts the data into hexadecimal, and stores it starting from the spec-
ified word + 2 in the CS/CJ-series CPU Unit.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits hex)
Always 0006 hex (6 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
(Undefined) Device
type
(2 digits hex)
Set the device type (1 character) in
ASCII.
+3
Device No. (6 digits hex)
Set the first read address of the device
to read.
+4
(Undefined)
+5
(Undefined) Device
words/
bits
(2 digits hex)
Set the number of device words/bits to
read.
Number of send data words
+0
+1
+5
PLC No.
Station No.
(Undefined)
+2
Device type
(Undefined)
Device No.
+3
+4
(Undefined)
First word of
send data
Number of device
words/bits
Offset
Contents (data format)
Data
+0
Number of receive data words
0003 to 00FA hex (3 to 250 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
Read data (4 digits hex)
Stores the number read data converted
into hexadecimal.
Receive data
storage words
Number of receive data words
+0
+1
PLC No.
+2
Station No.
Read data
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...