395
C-mode (Host Link) Command Master
Appendix C
703 (02BF)
LR AREA READ
Reads the contents of the specified number of LR Area
(CS/CJ Series: CIO 1000 to CIO 1199) words beginning
with the designated word from the specified Host Link
Unit and stores starting from the specified storage word.
Yes
Yes
704 (02C0)
HR AREA READ
Reads the contents of the specified number of HR Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Yes
Yes
705 (02C1)
TIMER/COUNTER
PV READ
Reads the contents of the specified number of timer/
counter PV words beginning with the designated word
from the specified Host Link Unit and stores starting from
the specified storage word.
Yes
Yes
706 (02C2)
TIMER/COUNTER
STATUS READ
Reads the contents of the specified number of timer/
counter status words beginning with the designated word
from the specified Host Link Unit and stores starting from
the specified storage word.
Yes
Yes
707 (02C3)
DM AREA READ
Reads the contents of the specified number of DM Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Yes
Yes
708 (02C4)
AR AREA READ
Reads the contents of the specified number of AR Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Yes
Yes
709 (02C5)
EM AREA READ
Reads the contents of the specified number of EM Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Yes
Yes
710 (02C6)
CIO AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated CIO Area word. Writing
is done in word units.
Yes
Yes
711 (02C7)
LR AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated Link Area (CS/CJ
Series: CIO 1000 to CIO 1199) word. Writing is done in
word units.
Yes
Yes
712 (02C8)
HR AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated HR Area word. Writing
is done in word units.
Yes
Yes
713 (02C9)
TIMER/COUNTER
PV WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated timer/counter PV word.
Writing is done in word units.
Yes
Yes
714 (02CA)
DM AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated DM Area word. Writing
is done in word units.
Yes
Yes
715 (02CB)
AR AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated AR Area word. Writing
is done in word units.
Yes
Yes
716 (02CC)
EM AREA WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated EM Area word. Writing
is done in word units.
Yes
Yes
717 (02CD)
STATUS READ
Reads the CPU Unit’s operating conditions (status) from
the specified Host Link Unit and stores in the words start-
ing from the designated word.
Yes
Yes
718 (02CE)
STATUS CHANGE
Changes the CPU Unit’s operating mode for the specified
Host Link Unit.
Yes
Yes
Sequence
No.
Communications
sequence name
Function
Ladder interface
Send word
allocation
Receive
word
allocation
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...