353
Error Logs
Section 11-4
ing from the beginning record number. The total number of bytes for the error
log data required is calculated as follows:
No. of records x 10 bytes
The configuration of each error log record is returned in 10 bytes, as follows:
Error Code and Details
Indicates the error contents of the error recorded. Refer to
11-4-4 Error Codes
and Details
.
Minute, Second, Day, Hour, Year, Month
Records the time the error occurred.
Comments
If the error log does not contain the specified number of records, the records
up to the last recorded stored at the time the command was executed will be
returned, and a normal response will be returned. The number of records
actually read will be returned as the number of stored records.
If the beginning record is specified higher than the current number of records
in the error log, an end code of 1103 Hex will be returned.
If the beginning record number is specified as 0000, the response will be com-
pleted normally, even if no error log is recorded.
If the number of records is set to 0000, the end code will be returned as 110C
Hex.
11-4-9 ERROR LOG CLEAR: 21 023
This command clears all stored error log records to 0.
Command Format
Response Format
Comments
The ERROR LOG CLEAR: 21 03 command clears the error log records that
are stored in the RAM error log table and the EEPROM error log table.
Minute
Second
Day Hour Year Month
Details
Error code
1st byte
10th byte
07
01
Command
code
03
21
Command
code
03
21
End code
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...