421
Host Link FINS Command Master
Appendix D
The values in parentheses are hexadecimal
The relationship between the Host Link FINS command code/response frame and the PMCR(260) instruction
operand is shown in the following diagram.
756 (02F4)
MEMORY AREA
WRITE
Sends command code 0102 hex to the specified Host
Link Unit and writes data to consecutive I/O memory area
words.
Yes
Yes
757 (02F5)
CIO AREA WRITE
Sends command code 0102 hex to the specified Host
Link Unit and writes data to consecutive CIO Area words.
Yes
Yes
758 (02F6)
DM AREA WRITE
Sends command code 0102 hex to the specified Host
Link Unit and writes data to consecutive DM Area words.
Yes
Yes
759 (02F7)
EM0 AREA WRITE
Sends command code 0102 hex to the specified Host
Link Unit and writes data to consecutive EM Area words
in Bank 0.
Yes
Yes
760 (02F8)
MEMORY AREA
FILL
Sends command code 0103 hex to the specified Host
Link Unit and writes the same data to consecutive I/O
memory area words.
Yes
Yes
761 (02F9)
CIO AREA FILL
Sends command code 0103 hex to the specified Host
Link Unit and writes the same data to consecutive CIO
Area words.
Yes
Yes
762 (02FA)
DM AREA FILL
Sends command code 0103 hex to the specified Host
Link Unit and writes the same data to consecutive DM
Area words.
Yes
Yes
763 (02FB)
EM0 AREA FILL
Sends command code 0103 hex to the specified Host
Link Unit and writes the same data to consecutive EM
Area words in Bank 0.
Yes
Yes
764 (02FC)
OPERATING MODE
CHANGE (RUN)
Sends command code 0401 hex to the specified Host
Link Unit and changes the CPU Unit’s operating mode to
MONITOR mode.
Yes
Yes
765 (02FD)
OPERATING MODE
CHANGE (STOP)
Sends command code 0401 hex to the specified Host
Link Unit and changes the CPU Unit’s operating mode to
PROGRAM mode.
Yes
Yes
766 (02FE)
UNIT DATA READ
Sends command code 0501 hex to the specified Host
Link Unit and stores the Unit data starting from the desig-
nated word.
Yes
Yes
767 (02FF)
UNIT STATUS
READ
Sends command code 0601 hex to the specified Host
Link Unit and stores the Unit’s operating conditions (sta-
tus) starting from the designated word.
Yes
Yes
Sequence
No.
Communications
sequence name
Function
Ladder interface
Send word
allocation
Receive
word
allocation
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...