459
Mitsubishi Computer Link Master (A-compatible 1C Frame, Model 1)
Appendix E
Device Memory Fill as Word Data (T/C Device Type)
(Sequence No. 813 (Hex 032D)) (Command Code: QW)
This sequence writes the word (PV) data starting from the specified word + 7 in the CS/CJ-series CPU Unit to
the number of device points starting from the specified device address for the specified device type (T, C) in the
Mitsubishi Computer Link Module with the specified station number (and the PLC number that follows).
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260)
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits hex)
0008 to 00FA hex (8 to 250 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
Device type (4 digits hex)
Set the device type (2 characters) in
ASCII.
+3
Device No. (5 digits hex)
Set the first write address of the write
data.
+4
(Undefined)
+5
(Undefined) Device
words/
bits
(2 digits hex)
Set the number of device words/bits to
write.
+6
Number of send data bytes
(4 digits hex)
Specify the number of text data bytes
for the communications line (i.e., twice
the number of text bytes in S+6
onwards)
+7
Write data (4 digits hex)
Set the write data.
+0
+1
+5
+2
+3
+4
+6
+7
Number of send data words
PLC No.
Station No.
Number of send data bytes
Device type
Device No.
Write data
First word of
send data
(Undefined)
(Undefined)
Number of device
words/bits
Offset
Contents (data format)
Data
+0
Number of receive data words
0002 hex or 0003 hex (2 or 3 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
Error code
(2 digits hex)
(Undefined)
Stores the error code converted to
hexadecimal. No error code is stored
for normal completion.
Receive data
storage words
Number of receive data words
+0
+1
PLC No.
+2
Station No.
Error code
(Undefined)
Содержание SYSMAC CJ1W-SCU21-V1
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi...
Страница 89: ...60 Basic Operating Procedure Section 1 9...
Страница 151: ...122 RS 232C and RS 422A 485 Wiring Section 3 4...
Страница 173: ...144 Host Link Function for Replacing Existing PLCs Section 4 6...
Страница 223: ...194 Enhanced Protocol Macro Functions Section 5 6...
Страница 277: ...248 Communications Frames Section 6 8...
Страница 291: ...262 Basic Operating Procedure in No protocol Mode Section 7 4...
Страница 301: ...272 Auxiliary Area and CIO Area Allocations Section 8 3...
Страница 391: ...362 Introduction Appendix A...
Страница 421: ...392 CompoWay F Master Protocol Appendix B...
Страница 513: ...484 E5 K Digital Controller Read Protocol Appendix F...
Страница 571: ...542 E5ZE Temperature Controller Write Protocol Appendix I...
Страница 587: ...558 E5 J Temperature Controller Protocol Appendix J...
Страница 627: ...598 ES100 Digital Controller Protocol Appendix K...
Страница 661: ...632 V500 V520 Bar Code Reader Protocol Appendix M...
Страница 697: ...668 3Z4L Laser Micrometer Protocol Appendix N...
Страница 717: ...688 Visual Inspection System Protocol Appendix O...
Страница 755: ...726 V600 V620 ID Controller Protocol Appendix P...
Страница 763: ...734 Hayes Modem AT Command Protocol Appendix Q...
Страница 767: ...738 Changing Communications Port Settings Using STUP 237 Appendix R...
Страница 781: ...752 Revision History...