7-2 Examples of Wiring for Each Application
7-2-5
Limit Switch Dual Channel Inputs and a Manual Reset
An example of the wiring and configuration when using the DST1-ID12SL-1 is shown
below.
Wiring
V
G
IN0
T0
IN1
T1
→
11
12
23
24
S1
E1
S2
IN
11
T1
S3
T2
G
GND
E1: 24-V DC Power Supply (S8
)
S1: Safety Limit Switch (D4D or D4B)
(positive opening mechanism)
S2: Limit switch
S3: Reset switch
Configuration
Parameter
group
Parameter name
Value
0008 Safety Input 0 Channel Mode
Test pulse from test output
0009 Safety Input 0 Test Source
Test Output 0
0054 Dual Channel Safety Input 0/1 Mode
Dual Channel Equivalent
Safety Input 0
0055 Dual Channel Safety Input 0/1 Discrepancy Time 100 x 10 ms
0012 Safety Input 1 Channel Mode
Test pulse from test output
Safety Input 1
0013 Safety Input 1 Test Source
Test Output 1
0052 Safety Input 11 Channel Mode
Used as standard input
0053 Safety Input 11 Test Source
Not Used
Safety Input 11
0064 Dual Channel Safety Input 10/11 Mode
Single Channel
Test Output 0
0001 Test Output 0 Mode
Pulse Test Output
Test Output 1
0002 Test Output 1 Mode
Pulse Test Output
Test Output 2
0003 Test Output 2 Mode
Power Supply Output
7-7
Содержание DST1 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ...DST1 series Safety I O Terminals Operation Manual Produced April 2005 ...
Страница 6: ......
Страница 24: ...Section 1 Overview ...
Страница 44: ...Section 2 General Procedure ...
Страница 50: ...Section 3 Configuration ...
Страница 63: ...Section 4 Specifications ...
Страница 67: ...Section 5 DST1 series ...
Страница 79: ...Section 6 Troubleshooting and Maintenance ...
Страница 87: ...Section 7 Wiring Examples ...
Страница 97: ...Appendices ...
Страница 114: ...Cat No Z904 E1 01 OPERATION MANUAL DST1 series Safety I O Terminals ...