1-3 Functions
1-3-3 Test
Outputs
Item Description
Any of the following five modes can be selected according to the external input
device.
Not Used
The corresponding test output is not used.
Standard Output Specifies connecting to the input for a muting lamp or PLC.
Used as a monitor output.
Pulse Test
Output
Specifies connecting a device with a contact output in
combination with the safety input.
Power Supply
Output
Specifies connecting to the power supply terminal of a safety
sensor. The voltage supplied from the test output to the I/O
power supply (V, G) is output.
Test output mode
Muting Lamp
Output
(terminal T3
only)
Specifies a muting lamp output.
When the output is ON, disconnection of the muting lamp can be
detected.
Output status after
communications
error
Sets the output state of the test output when a communications error occurs.
This parameter is enabled when the Test Output Channel Mode is set to
Standard
Output
or
Muting Lamp Output
.
Short-circuit
detection
Supported.
Broken wire
detection of
external indicator
Supported.
This setting is valid when Test Output Mode is set to
Muting Lamp Output
.
1-9
Содержание DST1 Series
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ...DST1 series Safety I O Terminals Operation Manual Produced April 2005 ...
Страница 6: ......
Страница 24: ...Section 1 Overview ...
Страница 44: ...Section 2 General Procedure ...
Страница 50: ...Section 3 Configuration ...
Страница 63: ...Section 4 Specifications ...
Страница 67: ...Section 5 DST1 series ...
Страница 79: ...Section 6 Troubleshooting and Maintenance ...
Страница 87: ...Section 7 Wiring Examples ...
Страница 97: ...Appendices ...
Страница 114: ...Cat No Z904 E1 01 OPERATION MANUAL DST1 series Safety I O Terminals ...