![Omron DeviceNet Safety Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/omron/devicenet-safety/devicenet-safety_system-configuration-manual_743566077.webp)
43
Menu List
Section 3-2
3-2-6
EDS File Menu
Note
The EDS File Menu can be displayed by right-clicking in the Hardware List
Window.
3-2-7
Tools Menu
3-2-8
Option Menu
Submenu
Description
Offline Online
Install
Installs an EDS file and adds a device to the Hardware
List.
(Normally there is no need to install the EDS files.)
O
O
Create
Creates a new EDS file and adds a device to the Hard-
ware List.
O
O
Delete
Deletes a device from the Hardware List. The installed
EDS file is also deleted.
O
O
Save As
Names and saves the EDS file of a device on the Hard-
ware List.
O
O
Find
Searches for a specified EDS file from the Hardware List.
O
O
Add to Network
Adds a device on the Hardware List to the virtual network. O
O
Property
Displays the properties of an EDS file.
O
O
Submenu
Description
Offline Online
Setup Parameters
Sets parameters by using explicit message communica-
tions.
×
O
Setup Node Address/Baud Rate
(only when DeviceNet is selected)
Sets the node address or baud rate of a device in the
DeviceNet network.
×
O
Setup TCP/IP Configuration (only
when EtherNet/IP is selected)
Makes TCP/IP settings, such as the IP address and sub-
net mask of a device on the EtherNet/IP network.
×
O
Submenu
Description
Offline Online
Select Interface
Selects an interface for the Network Configurator to use for
the network connection.
O
×
Edit Configuration File
Edits various configuration files.
(Normally not required.)
O
O
Setup Monitor Refresh Timer
Sets the monitor refresh timer values (monitoring cycles in
device monitoring).
O
O
Install Extend Module
Installs an Expansion Module.
(Normally not required.)
O
O
Install Interface Module
Installs an Interface Module.
(Normally not required.)
O
×
Parameter Auto Update when Con-
figuration Changed
The slave parameters registered in the Master will be
updated automatically when a slave parameter is
changed. The default is OFF (do not update). Under nor-
mal conditions, leave this option set to OFF. If slave infor-
mation registered in the Master does not match with the
slave information, an exclamation mark [!] will be displayed
below the device icon. (Refer to
2-1-2 Changing an Estab-
lished Safety Network
.)
O
O
Device Status Auto Update When
Connected Online
When this option is ON, if the device is online, its status
will be automatically detected and displayed.
O
×
Содержание DeviceNet Safety
Страница 1: ...SYSTEM CONFIGURATION MANUAL Cat No Z905 E1 07 DeviceNet Safety...
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ...DeviceNet Safety System Configuration Manual Revised July 2009...
Страница 6: ...iv...
Страница 11: ...ix TABLE OF CONTENTS Appendix 277 Glossary 333 Index 335 Revision History 339...
Страница 12: ......
Страница 14: ...xii...
Страница 18: ...xvi...
Страница 68: ......
Страница 98: ...64 Creating a Virtual Network Section 3 4 A new connected network will be created as shown below...
Страница 122: ......
Страница 167: ...133 Safety Slave Settings Section 5 2...
Страница 234: ......
Страница 266: ......
Страница 366: ......
Страница 372: ......
Страница 374: ......
Страница 375: ......