19
CX-Process Monitor Plus
Section 1-1
The Loop Control Unit/Board does not itself have HMI functionality. To monitor
function block operation status, it is thus necessary to connect and use the
CX-Process Monitor Plus.
Online
operation
functions
User Config-
uration
screen
Graphic
screen
Graphic elements representing plant process control can be pasted to Graphic
Screens from a library. These elements can be used to display changes in
plant status. Up to 200 Graphic Screens can be created.
• Library Figures and Image Elements
Text displays, straight lines, rectangles, rectangle with round corners,
ellipses, polygons, images
• Library Functional Objects
• Fixed Graphic Display Elements:
Text, instruments, thermometers, transmitters, orifices
• Changeable Graphic Display Elements:
Analog displays: Bar graph displays, numeric displays, tanks
Analog settings: Numerical settings
Contact display: Pumps, valves, pipes
Contact operation: Switches
• Elements for Screen Display:
Screen jump elements
FP switch (faceplate popup) elements
• Individual graphic screens can be saved as files or read.
• Multiple graphic elements can be grouped and saved as files or read.
Annunciator
screen
This screen notifies the operator of alarms or errors that occur by changing the
display color and emitting sound. At the same time, a 32-character message is
displayed over two lines on screen elements.
A total of 16 screen elements (4 columns
×
4 lines) can be displayed on each
screen. The maximum number of screens is 5.
Operation
Guide
Screen
This screen displays pre-registered 128-character messages over two lines
together with the date of occurrence when the specified internal switch is set to
ON.
Max. number of registerable messages: 1000, Number of display colors: 16
Up to 1000 messages are displayed in a single screen.
Output possible in CSV format.
System
Fixed screen
Alarm Log
screen
A record of alarms (time of error occurrence, tag name, PV or MV current
value at occurrence, alarm type, etc.) that occur and that are input from the
Control and Alarm blocks is saved and displayed as a list later.
Up to 1000 alarm messages are displayed in a single screen.
Output possible in CSV format.
Operation
Log screen
A record of operations using graphic screen data and switch objects and
changes made to ITEM data in the Loop Control Unit/Board in the Control or
Tuning Screen can be saved and later displayed as an operation log. The oper-
ation log includes the date and time of change, tag name, original ITEM data
setting, new ITEM data setting, etc.
Up to 1000 operation messages are displayed in a single screen.
Output possible in CSV format.
System
Monitor
screen
This screen displays the Loop Control Unit/Board system error information.
System
Monitor Log
screen
This screen displays a log of the run/stop history and a history of execution
errors that occur on the Loop Control Unit/Board together with the date of
occurrence.
Output possible in CSV format.
Item
Descriptions
Содержание CX-Process Monitor Plus 2
Страница 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Страница 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi Application Precautions 4...
Страница 41: ...26 Basic Operating Procedure Section 1 2...
Страница 243: ...228 Checking Configurations Section 5 7...
Страница 244: ...229 SECTION 6 Troubleshooting This section describes errors that can occur while using the CX Process Monitor Plus...
Страница 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Страница 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...