13
CX-Process Monitor Plus
Section 1-1
Loop Control Boards
1,2,3...
1.
Make the settings for the HMI in the System Common block (Block Model
000).
2.
Set tags as follows:
• Function block data: Set CSV tags.
• Individual contact signals: Set tags for Monitor Plus for the contacts in the
Internal Switch block (Block Model 209).
• Individual analog signals from LCU to computer: Set tags for Monitor Plus
for the analog signals in the Input Selection block (Block Model 162).
• Individual analog signals from computer to LCU: Set tags for Monitor Plus
for the analog signals in the Constant Generator block (Block Model 166).
Note
For both the Loop Control Unit and Loop Control Board, the follow-
ing function blocks must be created and connected separately to
enable monitoring and setting individual contact signals and indi-
vidual analog signals (i.e., other than function block data).
• To monitor and set individual contact signals, contact signals must be
input/output using the Contact Distributor block (Block Model 201) and
Internal Switch block (Block Model 209).
• To monitor individual analog signals, analog signals must be output
from the Input Selection block (Block Model 162).
• To set individual analog signals, analog signals must be input to the
Constant Generator block (Block Model 166).
Compile the Tag File for
the CX-Process Monitor
Plus.
The tag file for Monitor Plus must be compiled (
Execute – Create Tag File –
Monitor Plus Tag
).
Note
The following dialog box will be displayed if a tag file for Monitor Plus is output
while the CX-Process Monitor Plus is running.
Tag information will not be updated if a tag file for Monitor Plus is output dur-
ing CX-Process Monitor Plus operation. To update the tag file, restart the CX-
Process Monitor Plus.
Download Function Block
Data to the Loop Control
Unit/Board.
Download the function blocks.
Compile the Monitor Tag
Files.
Start the CX-Process Monitor Plus. In the Main Window, click the
Run
Button
or the
Setup
Button. The monitor tag files (mtagmst and mtagsubmst) will be
automatically generated based on the tag file for Monitor Plus (monitor.csv).
Содержание CX-Process Monitor Plus 2
Страница 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Страница 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 9: ...x...
Страница 15: ...xvi Application Precautions 4...
Страница 41: ...26 Basic Operating Procedure Section 1 2...
Страница 243: ...228 Checking Configurations Section 5 7...
Страница 244: ...229 SECTION 6 Troubleshooting This section describes errors that can occur while using the CX Process Monitor Plus...
Страница 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Страница 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...