100
Error Codes
Section 11-2
A.10
A.10
@
A.10
---
4010
Overcurrent
Overcurrent has occurred or radiator
overheated error was detected (3 to
15-kW models only).
---
---
---
16
Overload
The effective value of the torque com-
mand exceeded the overload level
that is set for Overload Level (Pn072).
---
---
---
18
4012
Regeneration over-
load
Regeneration energy exceeded the
processing ability of the regeneration
resistance.
---
---
---
21
4015
Encoder communi-
cations error
Communications between encoder
and Servo Drive have failed for the
specified number of times, causing
an error to be detected. (No response
to request from Servo Drive.)
---
---
---
23
4017
Encoder communi-
cations data error
Data communications error has
occurred, most likely due to noise.
---
---
---
24
4018
Deviation counter
overflow
The number of position deviation
pulses exceeded the setting for the
Deviation Counter Overflow Level
(Pn209).
---
---
---
26
401A
Overspeed
The motor speed exceeded the spec-
ified value for the Overspeed Detec-
tion Level (Pn.073).
---
---
---
27
401B
Command error
Operation command resulted in an
error.
---
---
---
29
401D
Internal deviation
counter overflow
The value of internal deviation
counter (Internal control unit)
exceeded 2 (134,217,728).
---
---
---
34
4022
Overrun limit error
The motor exceeded the allowable
motor operation range that is set for
the Overrun Limit (Pn.026) for the
position command input range.
---
---
---
36
4024
Parameter error
The data in the parameter save area
was corrupted when reading data
from EEPROM at powering ON.
---
---
---
37
4025
Parameter Crash
EEPROM write verification data was
corrupted when reading data from
EEPROM at powering ON.
---
---
---
38
4026
Drive prohibit input
error
The positive and negative drive pro-
hibit inputs (NOT and POT) were both
ON when the Drive Prohibit Input
Selection (Pn.004) was set to 0 and
the Stop Selection at Drive Prohibit
Input (Pn066) was set to 0 or 1.
Or, either the POT or NOT input was
ON when the Drive Prohibit Input
Selection (Pn.004) was set to 2.
---
---
A.28
---
No Code
(See note
1.)
Emergency stop
An emergency stop was input during
Servomotor operation.
---
---
---
40
4028
Absolute value sys-
tem down error
(absolute encoder
only)
Power supply to encoder and battery
power have dropped. Built-in capaci-
tor voltage has dropped below the
specified value (3.0 V).
Servo Drive display
Position
Control
Unit error
code
Error detection
function
Detected error or cause of error
W
Series
W-series
(Built-in
Communi-
cations
Type)
SMART-
STEP Jun-
ior (Built-in
communi-
cations
Type)
G-Series
(Built-in
communi-
cations
Type)
Содержание CX-MOTION-NCF - V1.8
Страница 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 21: ...xxii Application Precautions 5...
Страница 33: ...12 Connecting to PLC Section 2 2...
Страница 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Страница 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Страница 63: ...42 Editing Servo Parameters Section 5 2...
Страница 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Страница 89: ...68 Writing to Flash Memory Section 7 6...
Страница 95: ...74 Axis Monitor Section 8 2 2 Click the OK Button to start communications i e establish connection...
Страница 103: ...82 Axis Monitor Section 8 2...
Страница 104: ...83 SECTION 9 Test Run Operation This section describes the test run operations for each axis 9 1 Test Run 84...
Страница 109: ...88 Test Run Section 9 1...
Страница 133: ...112 Index...
Страница 137: ...116 Revision History...