![background image](http://html1.mh-extra.com/html/omron/cx-motion-ncf-v1-8/cx-motion-ncf-v1-8_operation-manual_744181099.webp)
78
Axis Monitor
Section 8-2
Axis Monitor Common Items
Selected Axis
Status
Basic Monitor
Name
Explanation
Title Bar
Shows the status of monitoring and communications between
Position Control Unit and Servo Drive.
• Stop: Monitoring stopped.
• Monitoring (Connection Released): Monitoring in progress,
however, communications between Position Control Unit and
Servo Drive have not been started. Therefore, information
about axes is not displayed.
• Monitoring (Connection Established): Entire information is
displayed.
Monitor Start/Stop
Button
Starts monitoring. If communications between Posi-
tion Control Unit and Servo Drive have not been
started, the connection will be established first.
Stops monitoring.
Close Button
Closes the monitor window.
Name
Explanation
Selected Axis
Specifies axes to be monitored. The axes registered in the
scan list of the Position Control Unit are displayed in the drop-
down list.
Name
Explanation
Status
Communications Status
Status of each signal is displayed.
SERVO ON
NC Unit Positioning Com-
pleted
No Origin Flag
Brake Output
Forward Rotation Limit Input
Reverse Rotation Limit Input
Origin Proximity Input
Encoder Phase Z Input
External Latch Signal 1 Input
External Latch Signal 2 Input
External Latch Signal 3 Input
Name
Explanation
Present Value
Present Value
Display
Present position, speed, etc. are displayed.
Monitor Setup
Button
Press this button to change displayed contents,
unit, and pulse rate.
Unit and pulse rate can be set only for the axes
registered in the Axis Map Setting Window.
Содержание CX-MOTION-NCF - V1.8
Страница 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 21: ...xxii Application Precautions 5...
Страница 33: ...12 Connecting to PLC Section 2 2...
Страница 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Страница 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Страница 63: ...42 Editing Servo Parameters Section 5 2...
Страница 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Страница 89: ...68 Writing to Flash Memory Section 7 6...
Страница 95: ...74 Axis Monitor Section 8 2 2 Click the OK Button to start communications i e establish connection...
Страница 103: ...82 Axis Monitor Section 8 2...
Страница 104: ...83 SECTION 9 Test Run Operation This section describes the test run operations for each axis 9 1 Test Run 84...
Страница 109: ...88 Test Run Section 9 1...
Страница 133: ...112 Index...
Страница 137: ...116 Revision History...