80
Axis Monitor
Section 8-2
Note
Monitoring the item specified in the upper box uses the Monitor Type 2 of the
Position Control Unit's Expanded Monitoring function. If the Monitor Type 2 is
set and being used in the ladder program, etc., do not set it on the Support
Software.
Status Monitor
Present Value Monitor
1,2,3...
1.
Click the
Setup
Button to display the Monitor Setup Window.
2.
Specify the type of monitored present value, unit, and pulse rate.
Pulse Rate
Unit
Specify the unit used for displaying values.
• command unit
• pulse
• inch
• mm
• degree
When command unit is set, setting numerator
and denominator of the pulse rate is invalid.
Numerator
Set the numerator of the pulse rate.
The setting range is from 1 to 4294967294.
Denominator
Set the denominator of the pulse rate.
The setting range is from 1 to 4294967294.
Name
Explanation
Name
Explanation
Servo Status
Operating Mode
Displays the operating mode
(Position, Speed, Torque).
Position: Positioning Completed Flag
Speed: Speed Conformity Flag
Displays the status of each
flag. The meanings of the
flags change depending on
the operating mode.
Position: Distribution Completed
Speed: Zero Speed Flag
Position: Positioning Proximity Flag
Torque: Speed Limit Status Flag
Torque Limit
Displays the status of each
flag.
Note
The Emergency Stop
Input Flag is displayed
for Position Control
Units with unit version
2.0 or higher.
Busy Flag
Origin Stop Flag
Stop Execution Flag
Forward Software Limit
Reverse Software Limit
Main Power Supply ON
Emergency Stop Input (See note.)
Name
Explanation
Present Value
Present Value
Display
Displays present positions, speed, etc.
The Monitor Type 1 and 2 of the upper 2 boxes
can be changed using the
Monitor Setup
But-
ton.
Feedback Present Position and Command
Present Position of the lower 2 boxes cannot be
changed.
Monitor Setup
Button
Press this button to change displayed contents,
unit, and pulse rate.
Unit and pulse rate can be set only for the axes
registered in the Axis Map Setting Window.
Содержание CX-MOTION-NCF - V1.8
Страница 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 21: ...xxii Application Precautions 5...
Страница 33: ...12 Connecting to PLC Section 2 2...
Страница 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Страница 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Страница 63: ...42 Editing Servo Parameters Section 5 2...
Страница 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Страница 89: ...68 Writing to Flash Memory Section 7 6...
Страница 95: ...74 Axis Monitor Section 8 2 2 Click the OK Button to start communications i e establish connection...
Страница 103: ...82 Axis Monitor Section 8 2...
Страница 104: ...83 SECTION 9 Test Run Operation This section describes the test run operations for each axis 9 1 Test Run 84...
Страница 109: ...88 Test Run Section 9 1...
Страница 133: ...112 Index...
Страница 137: ...116 Revision History...