Auxiliary Area Allocations by Address
Appendix D
A540
A540.10 Pulse Out-
put 0 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 0. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
---
Retained
Cleared
---
A541
A541.00 Pulse Out-
put 1 Reset
Bit
The pulse output 1 PV (contained in
A278 and A279) will be cleared when
this bit is turned ON.
---
Retained
Cleared
---
A278 and
A279
A541.08 Pulse Out-
put 1 CW
Limit Input
Signal Flag
This is the CW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
---
Retained
Cleared
---
---
A541.09 Pulse Out-
put 1 CCW
Limit Input
Signal Flag
This is the CCW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
---
Retained
Cleared
---
---
A541.10 Pulse Out-
put 1 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 1. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
---
Retained
Cleared
---
---
A562
A562.00 Error
Counter 0
Reset Bit
Turn ON this bit to reset the Error
Counter 0 Present Value and turn
OFF the Error Counter 0 Error Flag.
---
---
Cleared
---
---
A562.01 Error
Counter 0
Disable Bit
Turn ON this bit to hold the present
value of error counter 0.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
---
Cleared
---
---
A563
A563.00 Error
Counter 1
Reset Bit
Turn ON this bit to reset the Error
Counter 1 Present Value and turn
OFF the Error Counter 0 Error Flag.
---
---
Cleared
---
---
A563.01 Error
Counter 1
Disable Bit
Turn ON this bit to hold the present
value of error counter 1.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
---
Cleared
---
---
A580
A580.00
to
A580.03
FB Commu-
nications
Instruction
Retries
Automatically stores the number of
retries in the FB communications
instruction settings specified in the
PLC Setup.
0 to F hex
---
Cleared
Written at
start of
operation
A581
All
FB Commu-
nications
Instruction
Response
Monitoring
Time
Automatically stores the FB commu-
nications instruction response moni-
toring time set in the PLC Setup.
0001 to FFFF
hex (Unit: 0.1 s;
Range: 0.1 to
6553.5)
0000 hex: 2 s
---
Cleared
Written at
start of
operation
---
Addresses
Name
Function
Settings
Status
after
mode
change
Status at
startup
Write
timing
Related
Flags,
Settings
Word
Bits
Содержание CP1L-L14D Series
Страница 2: ...CP1L L14D CP1L L20D CP1L M30D CP1L M40D CP1L CPU Unit Operation Manual Revised June 2007...
Страница 3: ...iv...
Страница 9: ...x...
Страница 13: ...xiv TABLE OF CONTENTS...
Страница 21: ...xxii...
Страница 33: ...xxxiv Conformance to EC Directives 6...
Страница 65: ...32 Function Blocks Section 1 5...
Страница 153: ...120 CP CPM1A series Expansion I O Unit Wiring Section 3 6...
Страница 523: ...490 Troubleshooting Unit Errors Section 9 4...
Страница 531: ...498 Replacing User serviceable Parts Section 10 2...
Страница 563: ...530 Auxiliary Area Allocations by Function Appendix C...
Страница 611: ...578 Auxiliary Area Allocations by Address Appendix D...
Страница 638: ...605 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Страница 639: ...606 Connections to Serial Communications Option Boards Appendix F...
Страница 669: ...636 Index...
Страница 671: ...638 Revision History...