OMNI 4000/7000 Operations and Maintenance Guide
– Rev F
3-37
OMNICONNECT® Operations
By default, the flow computer automatically sets the first product (Product 1 in the list) as the
active product number for all batch stacks.
To access batch stack control settings, follow these instructions:
1.
In the Actions ribbon, click
Operate
.
2.
Expand the Control tree to see the
previously configured Meter Runs and
Stations under each batch group:
•
Go to Section 3.4.1 Meter Run
Configurations for information on how
to make changes to Meter Runs.
•
Go to Section 3.4.2 Station
Configurations for information on how
to make changes to Stations.
Two different groups of batch stacks are listed on the Control tree:
•
Stack Shift
– Using this option instructs the flow computer to end the batch on
the current running product, shift the batch stack upwards, and begin a new
batch on the first product in the batch stack. If a new product number is not
entered into the batch stack before ending the batch, the flow computer will not
shift the batch stack, and it will begin a new batch measuring the same product
as the batch that just ended.
•
No Stack Shift
– Using this option instructs the flow computer to end the batch
on the current running product and to begin a new batch measuring the same
product as the batch that just ended. The flow computer will not shift the batch
stack, even if there are products entered into the batch stack before ending
the batch.