Assign Gas Product to Meter Run
In liquid applications, products are assigned to Meter Runs using batches and batch stacks. Go to
Section 3.6
Batch Operations for more information on batches.
To assign a gas fluid product to a Meter Run, follow these instructions:
1.
In the Actions ribbon, click
Configure
.
2.
a. Expand a
Meter Run
in the
Configure
tree.
b. Click on
Flowmeter
to display its
configuration options in the screens
on the right.
3.
In the lower right-hand corner of the Setup
screen, select a product number in the
Flow Stream
group to assign that product
stream to that Meter Run.
4.
When you are finished with the
Setup
screen, click
Apply
to save your changes.
5.
Continue to assign products to other Meter
Runs, as needed.
This number corresponds to the
numbered gas fluid product
(1 through 6) listed under
Fluid
Products
in the
Configure
tree.