18. MALFUNCTION CODE
Field Service Ver. 1.1 May 2011
284
TROUBLESHOOTING
0094
2nd image transfer
pressure / retraction
failure
• The IDC sensor does not come into the condition where
the level detection is available (retracted position = IDC
sensor shutter is open) within a given period of time after
the 2nd transfer release solenoid has turned ON.
• The IDC sensor does not come into the condition where
the level detection is not available (pressed position = IDC
sensor shutter is closed) within a given period of time after
the 2nd transfer release solenoid has turned ON.
0096
1st image transfer
pressure / retraction
failure
• The 1st transfer release sensor is not activated (retracted
position) within a given period of time after the 1st transfer
release solenoid has turned ON.
• The 1st transfer release sensor is not deactivated (pressed
position) within a given period of time after the 1st transfer
release solenoid has turned ON.
0300
Polygon motor
malfunction
• The polygon motor does not rotate evenly even after the
lapse of a given period of time after it has been started.
• The motor lock signal remains HIGH for a given period of
consecutive time while the polygon motor is being rotated.
0310
Laser malfunction
• The SOS signal is not detected within a given period of
time after the output of the laser has been started.
0500
Heating roller warm-up
failure
• The thermistor /1 does not detect the specified tempera-
ture and the warm-up cycle is not completed even after the
lapse of a given period of time after the cycle has been
started.
0502
Thermistor open-circuit
failure
• The temperature detected by the thermistor/1 does not
reach a predetermined level even after the lapse of a given
period time after the warm-up cycle has been started.
0503
Thermistor resistance
failure
• The difference between the temperature detected by ther-
mistor/1 and that detected by thermistor/2 exceeds a pre-
determined value.
0510
Abnormally low heating
roller temperature
• The temperature detected by the thermistor /1 remains
lower than the specified value for a given period of time or
longer.
0520
Abnormally high heating
roller temperature
• The temperature detected by the thermistor /1 remains
higher than the specified value for a given period of time or
longer.
• The heater lamp remains ON for a given period of time or
longer.
0650
Scanner home sensor
abnormalities
• A low motor lock signal is not detected even after the lapse
of a predetermined period of time after the polygon motor
has been started.
• The motor lock signal remains HIGH for a predetermined
consecutive period of time while the polygon motor
remains energized.
0F52
Toner level sensor/Y
malfunction
• An error occurs on the toner level sensor for each color.
0F53
Toner level sensor/M
malfunction
0F54
Toner level sensor/C
malfunction
0F55
Toner level sensor/K
malfunction
Code
Description
Detection timing
d-Color MF2400
Содержание PF-P09
Страница 1: ...SERVICE MANUAL Color Printer d Color MF2400 PF P09 Code Y113750 1...
Страница 4: ...ii Blank Page...
Страница 27: ...SERVICE MANUAL Color Printer d Color MF2400 Code Y113750 1...
Страница 151: ...7 OTHER MAINTENANCE ITEM Field Service Ver 1 1 May 2011 108 MAINTENANCE Blank Page d Color MF2400...
Страница 436: ...SERVICE MANUAL Color Printer Code Y113750 1 SERVICE MANUAL PF P09...
Страница 440: ...Lower Feeder Unit PF P09 OUTLINE MAINTENANCE Field Service Ver 1 1 May 2011 ii ADJUSTMENT SETTING Blank Page...
Страница 442: ...1 PRODUCT SPECIFICATIONS Field Service Ver 1 1 May 2011 2 Lower Feeder Unit PF P09 OUTLINE Blank Page...
Страница 454: ...3 OTHER MAINTENANCE ITEM Field Service Ver 1 1 May 2011 14 Lower Feeder Unit PF P09 MAINTENANCE Blank Page...
Страница 457: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 12 2011 1ST EDITION 457 Y113750 1...