5. MECHANICAL ADJUSTMENT
Field Service Ver. 1.1 May 2011
16
Lower Feeder Unit
PF-P09
ADJUSTMENT
/ SETTING
5.
MECHANICAL ADJUSTMENT
5.1
Registration adjustment
This adjustment must be made if:
• The printed image deviates in the main scan direction, and the following setting
does not resolve a problem.
[SERVICE MODE]
o
[ADJUST]
o
[LEFT ADJUST]
1.
Remove the tray.
2.
Loosen two screws [1].
3.
Loosen two screws [1].
4.
Watching the graduations [2] on the
adjusting plate, move the edge guide
plate [3] as necessary.
Adjustment range:
r
2.0 mm
5.
Tighten the four screws that have
been loosened and mount the tray.
A00TF3C500DA
[1]
A00TF3C501DA
[2]
[1]
[3]
[1]