Electrical Wiring
This machine must be wired to a power source before use.
To connect the machine directly to the electrical panel (“Hardwiring”), ensure an electrical disconnect is
installed near the machine so the operator or service person can easily disconnect the machine from
power.
To connect this machine with a plug and a cord, use a UL/CSA listed plug that meets the power
requirements. Organize the power cord so it does not create a tripping hazard.
Refer to “Wiring Diagrams” on page 65 for wiring your machine to a power source.
Use the correct power cord type when connecting this machine to the power source. Use power cord
types with a voltage rating of 600V for 460V circuits. In addition, the ampacity rating of the power cord
or wires is determined by many factors. It is important to have the wiring work completed by a licensed
electrician, and the work must meet or exceed the requirements of the local electrical code. Otherwise,
the warranty is void.
Use a compatible strain relief to protect and secure the electrical wire at the exit hole of the connection
box. Use a compatible conduit connector if the machine is wired with armored cables or conduit.
Use ring-type or fork-type connectors to connect the wires to the terminals of the table saw.
This saw uses a three-phase motor. If the motor is running in reverse, swap any two of the incoming hot
wires in the junction box.
WARNING
Use properly sized wires that meet the power requirement of your machine. Using
undersized wires can cause overheating and increase the risk of fire and machine
damage.
WARNING
Improper copper-aluminum wire connection is a fire hazard. If the power circuit
available uses aluminum wires, use certified CU/AL wire connectors.
The use of an extension cord is not recommended. If you need an extension cord to connect to a power
source, select a durable cord type with a high-temperature rating (90C° or above). Use the minimum
amount of extension cord as needed.
Minimum cord size (AWG) required based on amperage draw and length of the cord:
Amps
Power Cord Length
25 feet
50 feet
75 feet
100 feet
8 to 12
14
14
12
10
12 to 15
12
12
10
10
15 to 20
10
10
10
NR
21 to 30
10
NR
NR
NR
*NR: Not Recommended
Содержание 4065
Страница 2: ......
Страница 10: ...10 Page Oliver Machinery 4065 Table Saw Identification...
Страница 11: ...4065 Table Saw OLIVERMACHINERY NET 11 Page...
Страница 67: ...4065 Table Saw OLIVERMACHINERY NET 67 Page Parts List Table and Blade Guard...
Страница 68: ...68 Page Oliver Machinery 4065 Table Saw Cabinet...
Страница 69: ...4065 Table Saw OLIVERMACHINERY NET 69 Page Motor and Blade Lift Assembly...
Страница 70: ...70 Page Oliver Machinery 4065 Table Saw Trunnion Assembly...
Страница 71: ...4065 Table Saw OLIVERMACHINERY NET 71 Page Rails...
Страница 72: ...72 Page Oliver Machinery 4065 Table Saw Extension Table...
Страница 73: ...4065 Table Saw OLIVERMACHINERY NET 73 Page Rip Fence Assembly...
Страница 74: ...74 Page Oliver Machinery 4065 Table Saw Miter Gauge...
Страница 84: ...84 Page Oliver Machinery 4065 Table Saw Maintenance Record Date Task Operator...
Страница 85: ...4065 Table Saw OLIVERMACHINERY NET 85 Page Notes...
Страница 87: ......