![OHAUS T72XW AM Скачать руководство пользователя страница 125](http://html1.mh-extra.com/html/ohaus/t72xw-am/t72xw-am_instruction-manual_3537195125.webp)
7000 SERIES INDICATORS
EN 117
TI
– TARE IMMEDIATELY
Command:
TI
Response:
TI_S_WeightValue_Unit Taring performed, stable tare value.
Response:
TI_D_WeightValue_Unit Taring performed, non-stable (dynamic) tare value.
Response:
TI_I
Command understood, not executable at present.
Response:
TI_L
The command is not executable.
Response:
TI_+
Upper limit of taring range exceeded.
Response:
TI_-
Lower limit of taring range exceeded.
Example
Command:
TI
Response:
TI_D_ _ _ _117.57_kg Tare taken with dynamic weight value.
Comments
Any previous tare value will be overwritten by the new tare weight value.
Tare weight values determined during motion may not be accurate.
The tare weight value is sent in the current units.
C.3 Report
In order to print reports of the Alibi Memory, Totalization registers, target table (Checkweighing application), ID
table (Counting application), a connection must be made for the “Reports” function. When a reports connection is
made to a serial port, whenever a report is run and then printed, it will be routed to the assigned port.
The line width of the printed report is selectable as either 40 characters or 80 characters in setup so that all reports
have the same general format. These formats are fixed and cannot be changed. A header and a footer consisting
of additional line feeds and the record separator character are also selected in the Reports sub-block of
Communications.
Samples of the Alibi Memory and totalization register reports in a 40 column wide and an 80 column wide print are
shown in the following sections. The remaining application specific reports are shown in the detailed Application
chapter of this manual.
Alibi Memory
The Alibi Memory can be viewed and printed. Alibi Memory is viewed by accessing the Operator menu (M key) and
then selecting the ALIBI icon
. A search screen is shown that can help reduce the number of records
retrieved to a manageable level.
After entering the desired search criteria, move focus to the START text and press
ENTER
. The Alibi Memory
report will be run and the first record will be shown on the display. Move through the results using the UP and
DOWN navigation keys. There is a scroll bar indicator on the right of the display to indicate where in the search
results the currently displayed record is positioned.
Pressing PRINT with any record shown will initiate a transmission of the results out the port programmed as
Reports. Examples with two records are shown in Figure C-1 and Figure C-2.
www.
GlobalTestSupply
.com
Find Quality Products Online at:
Содержание T72XW AM
Страница 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Страница 3: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Страница 4: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Страница 8: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Страница 142: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...