Parameter
No.
Name
Factory
setting
Super-
visor
P 1
P 2
P 3
P 4
P213
(P) ISD ctrl loop gain [%]
100
S
P214
(P) Torque precontrol [%]
0
S
P215
(P) Boost precontrol [%]
0
S
P216
(P) Time boost precontrol [s]
0.0
S
P217
(P) Oscillation damping [%]
10
S
P218
(P) Modulation depth [%]
100
S
P219
Auto. excitation [%]
100
S
P220 (P)
Parameter
identification 0
*) dependent on FI power or P200/P220
CONTROL PARAMETERS (5.4) Encoder input, only SK 520E/530E
P300
(P) Servo Mode [On / Off]
0
P301 Incremental
encoder
6
P310
(P) Speed controller P [%]
100
P311
(P) Speed controller I [%/ms]
20
P312
(P) Torque current controller P [%]
200
S
P313
(P) Torque current controller I [%/ms]
125
S
P314
(P) Limit torque current controller [V]
400
S
P315
(P) Field current controller P [%]
200
S
P316
(P) Field current controller I [%/ms]
125
S
P317
(P) Limit field current controller [V]
400
S
P318
(P) Weak field control P [%]
150
S
P319
(P) Weak field control I [%/ms]
20
S
P320
(P) Weak field control limit [%]
100
S
P321
(P) Speed control I brake off
0
S
P325 Encoder
function
0
P326 Encoder
conversion
1.00
P327
Speed slip error [rpm]
0 (off)
CONTROL TERMINALS (5.5)
P400
Analog input function 1eeeeeeee
1
P401
Analog on mode. 1
0
S
P402
Adjustment 1: 0% [V]
0.0
S
P403
Adjustment 1: 100% [V]
10.0
S
P404
Filter analogue input 1 [ms]
100
S
P405
Analog input function 2
0
P406
Mode analog input 2
0
S
P407
Adjustment 2: 0% [V]
0.0
S
P408
Adjustment 2: 100% [V]
10.0
S
P409
Filter analogue input 2 [ms]
100
S
P410
(P) Min. freq. aux. setpoint
[Hz]
0.0
P411
(P) Max. freq. aux. setpoint
[Hz]
50.0
P412
(P) Nom.val process ctrl [V]
5.0
S