3.2
Technology unit overview
BU 0500 GB
Subject to technical alterations
55
Menu structure level
Screen layout during parameterisation
If the setting of a parameter is changed, then the value flashes intermittently until confirmed with the ENTER
key. In order to retain the factory settings for the parameter being edited, both VALUE keys must be operated
simultaneously. Even in this case, the setting must be confirmed with the ENTER key in order for the change
to be stored.
If the change is not to be stored, then pressing one of the SELECTION keys will call up the previously stored
value and pressing a SELECTION key again will exit the parameter.
P102
PS1
3
Acceleration time
2.90
s
ONLINE
FI
P1
E ready
NOTE:
The lowest line in the display is used to display the current status of the box and the frequency
inverter being controlled.
NOTE:
The parameters P502, P701 to 706, P707, P718, P741/742 and P745/746 also have an array-
level in which further settings can be made. The required array level must first be selected (see
parameterisation, Section 5) and confirmed with ENTER. The required parameter setting can now
be made.
P502
PS1
[01]
3
Leading function value
Off
ONLINE
FI
P1
E ready
Parameter set to be edited
Parameter to be edited (No.)
Parameter to be
edited (text)
Current
parameter value
Actual status
of the
ParameterBox
Selected
control medium
Active parameter set
in control medium
Status of the control
medium
Array level of the
selected parameter.
E.g. [01], [02], [03]...