NORDAC SK 5xxE Manual
56
Subject to technical alterations
BU 0500 GB
3.2.4 ParameterBox parameters
The following main functions are assigned to the menu groups:
Menu group
No.
Master function
Display (P10xx):
Selection of operating values and display layout
Parametrierung (P11xx):
Programming of the connected inverter and all storage media
Parameter administration (P12xx):
Copying and storage of complete parameter sets from storage media and
inverters
Options (P14xx):
Setting the ParameterBox functions and all automatic processes
Parameter display
Parameter
Set value / Description / Note
P1001
Bus scan
A bus scan is initiated with this parameter. During this process a progress indicator is shown in
the display.
After a bus scan, the parameter is "Off".
Depending on the result of this process, the ParameterBox goes into the "ONLINE" or
"OFFLINE" operating mode.
P1002
FI selection
Selection of the current item to be parameterised/controlled.
The display and further operating actions refer to the item selected. In the inverter selection list,
only those devices detected during the bus scan are shown. The actual object appears in the
status line.
Value range: FI, S1 ... S5
P1003
Display mode
Selection of the operating values display for the ParameterBox
Standard:
Any 3 adjacent values
List:
Any 3 values with units below each other
Large display:
1 any value with unit
P1004
Values for display
Selection of a display value for the actual value display of the ParameterBox.
The value selected is placed in the first position of an internal list for the display value and is
then also used in the Large Display mode.
Possible actual values for the display:
current frequency
Voltage
Current
Speed of rotation
Torque current
Setpoint frequency
ZK voltage
Bus actual value1, non-standardised
P1005
Standardisation factor
The first value on the list displayed is scaled using the standardisation factor. If this
standardisation factor varies from a value of 1.00, then the units of the scaled value are hidden
in the display.
Value range: -327.67 to +327.67; resolution 0.01
Parametrierung
Parameter
Set value / Description / Note
P1101
Object selection
Selection of the item to be parameterised.
The ongoing parameterisation process relates to the object selected. Only the devices and
storage objects recognised during the bus scan are displayed in the selection list. If only one
frequency inverter is connected and no storage address occupied, this parameter is not
displayed!
Value range: FI, S1 ... S5